Festo DGPI AIF Serie Instrucciones De Utilizacion página 33

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
DGPI(L)−...−AI F
9
Care and maintenance
Maintaining the band system:
Clean the band system if required with a soft cloth.
S
The following cleaning agents are permitted: all non−abrasive media.
Lubricate the surface of the band system if it no longer has a layer of grease.
S
Grease type: LUB−KC1 (silicon−free) from Festo.
Lubricating the roller bearing of types DGPIL−...:
1. Make sure that the lubrication intervals in accordance with Fig. 25 are ob
served. If the device is not operated frequently, lubrication should take place
at the latest after 3 years.
Lubrication intervals and grease types
The first lubrication
The following interval with LUB−KC1
Or: The following interval with LUB−RN2
Fig. 25
S Note that lubrication must be undertaken more often:
in dusty and dirty environments
with work strokes of < 50 mm
at speeds of > 2 m/s.
2. Exhaust the DGPIL−... .
3. Grease the roller bearings on all four
lubrication nipples.
For this purpose use a grease gun with
pinpoint nozzle (see Accessories").
S Push the slide backwards and forwards
during lubrication. Otherwise the
grease cavities will not be filled to an
equal extent.
4. Lubricate the surface of the band system if it no longer has a layer of grease
(grease type: see Fig. 25).
Festo DGPI(L)−...−AIF 0409a English
5000 km
400 km
5000 km
Fig. 26
33