A BC D EF
7
12
13
FIG.2
10
11
FIG.3
20
9
FIG.4
PAGE
B
FIG.1
8587-01
FIG.6
WHITE SUPPLY
WHITE OR IDENTIFIED
WIRE
FIXTURE WIRE
UL LISTED
WIRENUTS
BLACK SUPPLY
PLAIN OR BLACK
WIRE
FIXTURE WIRE
BARE, OR GREEN
BARE, OR GREEN
GROUND WIRE
FIXTURE GROUND
FROM SUPPLY
WIRE
FIG.5
4
of
4
SPEC.NO.
023835 Rev. C
WARNING: National Electrical Code, Article 110-3 (b), states that "Listed or labeled equipment shall be used
or installed in accordance with any instructions included in the listing or labeling". Use only Progress Lighting
UL listed trims. Use of other trims not listed in this fixture, including those that are UL classified, is a violation
of N.E.C. 110-3 (b) and voids all warranties.
WARNING: When using special control devices with this fixture, follow instructions carefully to ensure N.E.C.
compliance. For more help, contact a qualified electrical contractor.
WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects
and/or other reproductive harm. Thoroughly wash your hands after installing, handling, cleaning, or otherwise
touching this product.
WARNING: Thermal insulation may be installed in direct contact with the fixture, but DO NOT install insulation
in excess of eight inches deep above fixture. Greater depth may cause the thermal protector to cycle the
fixture on or off.
WARNING: Use only those trims, lamps, and maximum wattages proper for this fixture, as indicated on the
label within the fixture.
1. For Wooden Joists: Extend the Bar Hangers (6), use joist alignment tabs (4) to locate fixture and position
underneath the support joist (8). Drive the 4 Nails (7) into Joists (8) (Fig. 1). Drive additional nails through
holes in Bar Hanger for alternate support if required.
2. For Suspended Ceilings: Place the Fixture on the ceiling grid with the "T" Bars (9) running through the Bar
Hanger Notches (10). Using a flat head screwdriver or other tool, bend the integral t-bar mounting tabs (11)
downward to a vertical position (Fig. 2 & 3). Secure housing to support structure with tie wire (supplied by
others) in the holes supplied. Secure the housing to the inverted t-bar with sheetmetal screws (supplied by
others) in the holes supplied (20).
3. Locate Housing along Bar Hanger in desired position and, using pliers, squeeze the 4 Locking Tabs (12) on
the Plaster Frame (13) tightly over the Bar Hangers to prevent further Housing movement. Set screws (1) are
provided that can be tightened to lock the housing on the hanger bars.
4. As desired, hanger bars (6) may be shortened at score mark to fit tight mounting conditions and joist
alignment tabs removed to adjust vertically as needed by breaking off with pliers.
5. Unsnap Junction Box Cover (14) by lifting the Leaf Spring (24).
6. Run supply wires through UL Listed connectors (not supplied) in one of the five Pryouts (15) on the Junction
Box (16) or Type NM cable (ROMEX) through an Opening above the Wire Retaining Plate (17). Connect
Supply Wires (19) as shown in Fig. 4 & 5. Replace Cover.
7. FOR AIR-TIGHT APPLICATIONS: This Progress product is Air-Tight approved per ASTM E283 testing
standards and complies with Washington State Energy Code requirements. To complete the installation of this
Air-Tight product, the opening between the ceiling (22) and housing edge (3) must be sealed by the installer
using silicone caulking, tape, or any other means acceptable to the local code official. Progress Lighting
Gasket Kit 8587-01 (purchased separately) can be used for this purpose (Fig. 6).
8. Select a Trim from the Wattage Label inside the Housing. Use Only Lamp Types and wattages approved for
the Trim chosen. DO NOT EXCEED MAXIMUM LISTED WATTAGE(S)!
9. To gain access to junction box (16) after ceiling is finished, remove the three screws (21) that hold the
housing (3) in place. Lower the housing. Remove screw (2) and access door (5) located inside housing.
Junction box cover plate (14) can now be removed for service.
INSTRUCTION SHEET MUST BE REMOVED FROM FIXTURE PRIOR TO ENERGIZING.
10/02/12
Assembly & Installation Instructions
CAUTION:
Read instructions carefully and turn electricity off at main
circuit breaker panel before beginning installation.
P821-AT
PAGE
1
of
4
SPEC.NO.
023835 Rev. C
10/02/12