American Standard DXV Landfair D35107.640 Instrucciones De Instalación página 3

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4
ADJUST HOT LIMIT STOP (MUST BE DONE WITH TRIM REMOVED)
By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the
HOT LIMIT SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water
temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1).
• Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to HOT
LIMIT STOP (1)
forward and rotate counterclockwise one number to limit hot water temperature.
Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1)
for indication.
5
BACK TO BACK INSTALLATION
(SEE ILLUSTRATION STEP 7 FOR REFERENCE)
• Remove Handle and Trim from Valve. See
step 3 for reference.
• Remove PRESSURE BALANCE UNIT (5). Rotate
PRESSURE BALANCE UNIT (5) 180˚ so that the inlets
face up and the large outlet port faces down.
• Push PRESSURE BALANCE UNIT (5) in casting make
sure inlets line up with holes in bottom of casting. Top
• Reassemble FIXATION RING (4) and CARTRIDGE (1).
7
TO GAIN ACCESS TO VALVE FOR SERVICING
• Remove Handle and Trim from Valve. See step 3 for reference.
• Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve, if present.
VALVE LEAKS WHEN SHUT OFF
• Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and
pull out PRESSURE BALANCING (5) unit.
• Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6).
Remove CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).
• Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws. Turn on water supply and see
above for installing TRIM and HANDLE.
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
• Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7) and clean valve thoroughly.
• Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair
Part M952100-0070 if balancing unit is defective.
• Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.
6
8
7
5
2
4
1
9
3
2
- 3 -
(1). Pull
3
5
1
4 4
COLDER
(Larger Numbers)
0 1 3 5 7 9 11 13 15
6
TEST INSTALLED FAUCET
• Turn VALVE "off".
• With HANDLE in "off" position, turn on water supplies
and check all connections for leaks.
DIVERTER and check SHOWER for proper operation.
• Check SPOUT and SHOWER connections for leaks.
LARGE OUTLET
5
INLETS
BACK TO BACK INSTALLATION
3
2
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
5
1
˚
ROTATE 180
M 965541 Rev. 1.2

Publicidad

Tabla de contenido
loading

Tabla de contenido