Automatic Digital
Blood Pressure
Wrist Monitor
01-506
Model
thIs quIck start guIde Is INteNded as
a suPPlemeNt to the INstructIoN
maNual. Please read the comPlete
maNual PrIor to fIrst use.
Before applying your blood pressure cuff, be sure your
wrist is within the appropriate range:
wrist circumference 5-1/2" – 7-5/8" (14-19.5 cm)
A 15 minute resting period is needed to stabilize the
body prior to taking a reading. No eating, drinking or
smoking while resting.
applying the Wrist cuff
1. Be seated at a table or desk with your feet flat on
the floor. Hold your left arm in front of you with
your palm facing upward.
2. Apply the preformed cuff to your left wrist
so that the digital display face is
positioned on the inside area of your wrist
facing you.
3. Adjust the cuff 1/4" - 1/2" from the edge of
the head of the ulna bone. The cuff should
fit comfortably, yet snugly around your
wrist.
If you have aNy questIoNs or are exPerIeNcINg dIffIcultIes, Please call the
toll-free customer servIce helP lINe for further assIstaNce at 1-866-326-1313.
taking the measurement
1. Rest your elbow on a solid
surface with your palm
facing upward. Elevate your
arm so that the cuff is at the
same level as your heart. Be
certain that cuff is elevated
to the proper level; you may
choose to support your
hand with a folded towel or
book. Relax your left hand.
2. Press the POW R button to turn
the unit on; the unit will run a self-
test, Fig 1.
3. The cuff will automatically inflate
to approximately 190mmHg or 40
mmHg higher than the last systolic
pressure reading stored in
memory.
4. When the measurement is
complete and the cuff deflates,
your blood pressure measurement
and pulse will display
simultaneously on the display
screen. Both the systolic and
diastolic readings will display at the
same time, Fig 2.
5. Consult the included Instruction Manual for information on
interpreting your reading results.
6. The results will automatically be stored in memory up to 60
readings.
7. Select
POW R to turn the unit off and conserve energy
and battery life. The unit will automatically shut-off and
revert to time/date mode after approximately 1 minute.
Please Note:
• You can stop the inflation or deflation process of
the cuff at any time by pressing the
button.
• Many factors such as genetics, age, sex, altitude,
physical activity, anxiety, muscular development,
certain medications or even the time of day can
influence blood pressure.
• Blood pressure varies from moment to moment;
even readings taken after proper rest periods can
vary. Home blood pressure readings may vary as
much as 10-20 points from ones taken at your
doctor's office.
• Variations in your individual readings should only
be interpreted by your physician or trained health
care professional.
• We encourage you to consult with your physician to
achieve the maximum benefit from your blood
Fig. 1
pressure monitor.
Fig. 2