Connecting to the power supply
Figures a/b:
A Transformer
B Extension cable
C Infra-red electronics
Connect power supply line 2 x 1.5mm
Electrical installation work must only be performed by a qualified electrician.
This work must be performed in accordance with regulations IEC 364-7-701-1984 (corresponds
to VDE 0100 Part 701) as well as all national and local regulations.
Install the protective tube (~28mm) for the extension cable between the transformer
and infra-red electronics
The extension cable between transformer and infra-red electronics must be routed through the protective
tube.
Technical Data
Supply voltage
Power consumption
Reception range
Flow volume
-Pre-flush
-Flush cycle
Intermediate flushing
72 hour flushing
Minimum delay time
Connection lines
Transformer - IR electronics:
Software class
Type of protection
Special accessory (Infra-red remote control 36206)
1.) Setting the range of reception
2.) Setting the flush duration
3.) Actuating lifting magnet
4.) Block lifting magnet (permanent stop)
5.) Resetting the basic setting
6.) Test mode
7.) 72-hour flush (factory setting: On)
Press and hold down the RESET button,
then also press the OFF AUTO button within 2 s
On = 4 short flashes/ Off = 2 long flashes
8.) Pre-flush (factory setting: Off)
Press the TEST button, press the ON AUTO button
On = 4 short flashes/ Off = 2 long flashes
9.) Intermediate flushing (factory setting: On)
Press the TEST button, press the OFF AUTO button
On = 4 short flashes/ Off = 2 long flashes
10.) Adjustment of the minimum delay time (factory setting: 7 s)
Press the TEST button, press the +/- button
4 short flashes = adjusted by one increment (approx. 1 s)
2 long flashes = final setting reached
Quit by pressing the TEST button or after 60 s
Approval and conformity
This product conforms to the requirements
of the relevant EU guidelines
The conformity declarations can be obtained from the following address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
3
2
(electrician)
230 V AC, 50/60 Hz
18.7 VA
70cm in front of the wall (adjustable with remote control)
0 l/ 2 l, factory setting 0 l (adjustable with remote control)
2-6/9 l, adjustable, factory setting: full flow volume
every 60 min (3 x) can be switched off with remote control
can be switched off with remote control
factory setting 7 s (adjustable with remote control)
extension cable (max. 25m)