This will allow the board to be removed from
the unit by simply pulling the sticky board
downwards. To remove the upper tube simply
grasp and rotate the tube 90° until 2 clicks are
heard. The tube may now be withdrawn by
sliding out of the lamp holders.
Fold the board retainer tabs back into their
original closed position and close the front
cover. Looking at the front of the unit now you
can clearly see the two upper keyhole mounting
points. Using the unit as a template, mark off
the two fixing points on the mounting surface,
ensuring that the unit is level (alternatively, the
paper template supplied can be used).
Figure 3 – Marking the fixing points (Sticky board & Upper
Tube removed)
Drill to a depth of 40mm using a No 8 drill. Place
the plastic plugs into the wall then screw the
screws into the plastic plugs leaving the head of
the screw approximately 10mm from the wall.
Should the wall be of plasterboard, stud
partition etc, we recommend to repeat the
above procedure with the lower two fixing
points.
The unit will now hook over the screws because
of the keyhole feature. You must now fully
tighten the screws so that the unit is properly
secured to the wall and ensure the screw heads
do not prevent the fitting of the sticky board.
You can now re-install the tube and sticky board,
which is the opposite procedure to removal.
Secure the power cord to the wall or other firm
surface prior to connecting to the supply.

CLEANING AND MAINTENANCE

To maintain the attractive appearance of the
units, wipe down and clean as often as required.
Use a cloth dampened with water and detergent
or a proprietary cleaner. Do not use scouring
pads or abrasives. The UV tubes in electric fly
traps should be changed at least once per year,
to maintain maximum efficiency replace with
Quantum tubes. Tubes are most attractive to the
target flying insects when less than one year old.
This is because the UV light emitted by the
tubes at a wavelength of 350-375 nanometres
diminishes with use. Light of this wavelength is
invisible to the human eye. Daily switching on
and off of the lamps results in an even faster loss
of the effective UV emission.
Therefore leave the tubes switched on
continuously and change them at least once
per year (preferably at the onset of increased fly
activity after the winter).
Use only PestWest shatter-resistant (coated)
Chameleon® VEGA
Quantum tubes with Reflectobakt® technology
(aluminium reflector). shatter-resistant coatings
allow for use in glass exclusion zones. The
coating on tubes supplied by PestWest is of
the highest quality available, using a material,
FEP that is both UV and operating temperature
tolerant, whilst allowing high emissions of the
critical UV light. The Reflectobakt® aluminium
reflector technology maximises UVA lamp
output power and prevents premature drying of
the sticky board.
RENEWING STICKY BOARDS
Switch off the machine before servicing. Sticky
boards should be changed when full or at least
every 6-8 weeks. Regular inspections of the
sticky boards are recommended, as they are
not entirely visible in normal operation. Ensure
PestWest glue boards are used as replacements.
Open the front cover by lifting outwards from
the bottom (Note: when the cover is opened
approximately 45
0
it will stay open on its own).
To remove the sticky board you must first twist
the board retainer tabs at the bottom of the
unit outwards. This will allow the old board to
be removed from the unit by simply pulling the
stick board downwards.
The sticky board has a perforation line about
30mm from the edge that allows this small
section of the sticky board to be folded at a
90degree angle. This folded section of the board
will help catch any debris falling from the upper
part of the sticky board. Before removing the
backing paper you need to fold this section and
then remove the backing paper from the new
sticky board.
Figure 4 – Folding the sticky board in place
Slide the sticky board into position in the
machine, sticky side facing the UV tubes,
ensuring they click into place under the sprung
retainers at the top of the machine. Fold the
board retainer tabs back into their original
closed position so that they hold the folded
section of the sticky board in place and close the
front. You can now switch the unit back on.

REPLACEMENT PARTS

Sticky board types: 135-000047 & 135-000063
(PestWest Chameleon range boards).
Tube type: 130-000177 (PestWest Quantum 14W
21" / 53cm).
To insure a safe use and optimum performance
only fit the above original parts.
CHANGING THE TUBES
Switch off the machine before servicing. Open
the front cover by lifting outwards from the
bottom (Note: when the cover is opened
approximately 45degrees it will stay open on
its own). Grasp and rotate each tube 90° until
the 2 clicks are heard. The tubes may then be
withdrawn by sliding out of the lamp holders.
Replacing the tubes is the opposite procedure
to removal. Close the front cover and switch the
unit back on.
TO FIT THE REFLECTOBAKT® SLEEVE
Remove the old lamp(s) from the machine.
Carefully pull off the Reflectobakt
the lamp. (It clips around the circumference
of the lamp). Take your new lamp and line up
the two leading edges of the Reflectobakt
sleeve with the pairs of pins at either end of
the lamp (see Fig 4). Ensure that the sleeve is
fitted centrally to the lamp so that the small
gap between the end of the sleeve and the
metal end of the lamp is the same at both ends.
Carefully push the sleeve so it is in contact along
the length of the lamp surface. It should grip
and stay in position. Re-fit the lamp into the
lamp holders then turn the lamp through 90
quarter turn or two clicks on the lamp holder).
This should position the sleeve at the back of the
tube, keeping the light off the glue board. Close
the front cover and switch the unit back on.
Figure 4 - Method of assembling Reflectobakt® showing
alignment in relation to pins:
Manufacturer reserves the right to vary model specifications
without notice
GUARANTEE
All PestWest units are supplied with 3 year
guarantee (excluding tubes).
®
sleeve from
®
(a
O
3

Publicidad

Tabla de contenido
loading

Tabla de contenido