Important Notice; Emergency Stop - ABB C579 Manual Instructivo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 4
Note! This product is obsolete. For replacement see Sentry safety relays.
Extension Device
Operating Instructions
Read and understand these instructions before installing,
operating, or maintaining the equipment.
DANGER
!
Hazardous voltage.
Will cause death or serious injury.
Turn off and lock out all power supplying this device before
working on this device.
CAUTION
Reliable functioning of the equipment is only ensured with certi-
fied components.
The devices must be installed in a switchgear cabinet with the IP32,
IP43 or IP54 degree of protection, depending on the ambient conditions.

IMPORTANT NOTICE

The products described herein are designed to be components of a custom-ized
machinery safety-oriented control system. A complete safety-oriented system
may include safety sensors, evaluators, actuators and signaling components. It
is the responsibility of each company to conduct its own evaluation of the effec-
tiveness of the safety system with the help of suitably trained persons. ABB AG
and its subsidiaries and affiliates (collectively "ABB") are not in a position to
evaluate all of the characteristics of a given machine or product or machine not
designed by ABB.
ABB accepts no liability for any recommendation that may be implied or stated
herein. The warranty contained in the contract of sale by ABB is the sole war-
ranty of ABB. Any statements contained herein do not create new warranties or
modify existing ones.
Application
The C579 is used to expand the enabling circuits. You can combine it with any
C579 basic unit. The max. achievable Performance Level PL / Cat. according to
DIN EN ISO 13849-1, and / or SIL according to DIN EN / IEC 62061 is the same as
for the basic device, when the external circuit (connection between basic device
and expansion unit) has been carried out in a failsafe way. The user must carry
out an evaluation of the overall systems.
Functions and connections
The C579 has four safe enabling circuits as NO circuits and one positively-driven
NC circuit. Two LEDs indicate the operating condition.
The C579 can be controlled via any enabling circuit in the basic unit. NC circuit
51/52 of the C579 is looped into the feedback circuit of the basic unit.
The internal circuit is functionally tested by the upstream basic unit.
Terminal
Operating
A1
voltage
A2
assignments
Outputs
13, 14
23, 24
33, 34
43, 44
Feedback
circuit
51, 52
Cable lengths
C579- 24V AC/DC
115V AC
230V AC
Figures
Fig. I:
Dimension drawings (dimensions in mm)
Fig. II:
Installation
Fig. III:
Safety data
Fig. IV:
Internal circuit: ¿ Power pack, À Control logic,
Á Channel 1, Â Channel 2
Fig. V:
Guard door monitoring
Fig. VI:

EMERGENCY STOP

Fig. VII:
EMERGENCY STOP with time delay
2
L/+
N/–
Enabling circuit 1 (NO contact)
Enabling circuit 2 (NO contact)
Enabling circuit 3 (NO contact)
Enabling circuit 4 (NO contact)
C579 monitoring (NC contact)
max. 1000 m
max. 300 m
max. 80 m
Order No.: 2CDC 113 022 M9701
Operating states
LED
Channel 1
Channel 2
Technical data
Permissible ambient temperature T
u
- Operation
- Storage
Degree of protection to DIN EN / IEC 60529
Rated insulation voltage U
i
Rated impulse withstand voltage U
imp
Rated control supply voltage U
s
Rated power
DC operating range
AC operating range 115 V / 230 V
AC operating range 24 V
Shock resistance (half-sine)
as per DIN EN / IEC 60068
Weight
Recovery time C579
24V AC/DC
Recovery time C579
115/230V AC
Release time C579
24V AC/DC
Release time C579
115/230V AC
Response time C579
24V AC/DC
Response time C579
115/230V AC
Utilization category
Rated operational
per
voltage U
e
DIN EN / IEC 60947-5-1
AC-15
230
DC-13
24
115
230
Continuous current I
th
Short-circuit protection Fuse links
for release circuit
Duty class
for enabling circuits and
Please adhere to the respective user information!
signaling circuits
(Order No.: C98130-A7524-A1-05-7419)
Be sure to fit the specified fuses. Otherwise safe interruption
in the event of a fault cannot be guaranteed.
For further data and accessories see Catalog.
C579
DIN EN / IEC 60947-5-1
English
Operation
PS
Enabling circuits
ON
Closed
Open
Faults
• Relay fusion-welded
• Defect in electronics
• Motor contactor fusion-welded
• No supply voltage
25 to +60 °C
40 to +80 °C
IP40, IP20 at terminals
300 V
4 kV
24 V AC / DC, 115 V AC, 230 V AC
2 W
0.85 to 1.2 x U
s
0.85 to 1.1 x U
s
0.80 to 1.1 x U
s
8 g / 10 ms
max. 0,26 kg
50 ms
100 ms
max. 25 ms
max. 80 ms
max. 30 ms
max. 200 ms
Rated operational
/ (V)
current I
/ (A)
e
with all enabling circuits loaded
40 °C
50 °C
60 °C
70 °C
5
4
3.5
3
5
4
3.5
3
0.2
0.2
0.2
0.2
0.1
0.1
0.1
0.1
5
4
3.5
3
DIAZED
gL (gG) 6 A / quick response 10 A

Publicidad

Tabla de contenido
loading