Before You Begin (cont.)
CAUTION: Risk of personal injury. Connect the toilet
electrical supply to a circuit protected by a dedicated
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current
Device (RCD).
Observe all local electrical codes.
Waste Outlet Pipe Information
4" PVC
IMPORTANT! Make sure that the height of the waste outlet pipe is
sufficient so the rubber ribs on the adapter will be fully inserted into
the waste outlet pipe.
The 4" PVC waste outlet pipe is wider than the stud pocket in a
2x4 installation. This requires that you carve out the wall material
on both sides of the installation wall to fit the waste pipe.
The center of a 4" PVC waste outlet pipe should follow the
guidelines provided in the "Install Framing and Waste Outlet"
section.
3" PVC
A PVC or flexible coupler may be wider than the stud pocket in a
2x4 installation. This requires that you carve out the wall material
on both sides of the installation wall to fit the waste pipe.
The center of a 3" PVC waste outlet pipe should follow the
guidelines provided in the "Install Framing and Waste Outlet"
section.
Cast Iron
A cast iron waste pipe will not be centered inside 2x4 framing,
and will protrude beyond the back of the stud pocket. Use 2x6
framing or build a chase behind 2x4 framing for cast iron waste
pipes.
The center of a KOHLER K-7208 cast iron waste pipe should
follow the guidelines provided in the "Install Framing and Waste
Outlet" section.
Kohler Co.
3
1246750-2-C