Kawasaki FT730V-EFI Manual Del Propietário página 34

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

32 MAINTENANCE
A. Inspection Ports
Install the air cleaner cover (See Air Cleaner Serv-
ice section in this chapter).
Cylinder and Cylinder Head Fins
Every 100 hours of operation, check and clean
the cooling fins and the inside of engine shrouds to
remove grass, chaff or dirt clogging the cooling sys-
tem and causing overheating.
NOTE
If a torque wrench is not available, this item
should be serviced by an authorized Kawasaki
engine dealer or equally qualified service facility.
Remove the quick rivets and guard [A].
Remove the air intake screen bolts and air intake
screen [B].
Loosen the clamp [C].
Remove the regulator ground bolt [D].
Disconnect the regulator connectors [E].
Remove the fan housing bolts [F].
Loosen the fan housing bolts [G].
Disconnect the tube [H] and remove the fan hous-
ing [I].
NOTE
Cover the intake port of the throttle body to keep
dust out of the opening.
Clean the cylinder and cylinder head fins.
Install the removed parts.
NOTE
Do not pinch the ignition coil leads [J] to installing
the fan housing.

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido