6. Wiring. (cont.)
[PLEASE NOTE: Wall and/or handheld remote
control must be used for fan to operate. If you do
not wish to use the wall control, please proceed to
Section 7 below to continue with fan installation.]
To install wall control, remove existing wall
switch. Wire one of the wall controls with wire
connectors provided as shown in diagram at right.
*Wrap each wire connector separately with
electrical tape as an extra safety measure. Gently
push wires and taped wire connectors into outlet
box.
Install one battery (included) in wall control.
IMPORTANT: Wall control will not function unless
battery is installed.
Since this fan comes with incandescent bulbs, the
dimmer switch (labeled ON and D) has been
pre-set to the "ON" position (ON). If you do not
wish to have dimming capability, please move the
switch to the "OFF" position (D).
Attach wall control to outlet box and secure with
screws from original wall switch. Attach plate
(included) to wall control using 2 screws provided
with the wall control.

7. Canopy Assembly.

Locate 2 screws on underside of hanging
bracket.
Lift canopy to hanging bracket. Align holes in
canopy with holes in hanging bracket. While
holding canopy in place, slide anti-sway adapter
up to canopy. Align holes in anti-sway adapter
with holes on underside of canopy and then
re-insert the screws that were previously
removed. Tighten both screws securely.
Slide canopy up to anit-sway adapter, aligning
rounded part of slotted holes in canopy cover
with screw heads in bottom of anti-sway
adapter. Turn canopy cover to the right
(clockwise) until it stops.
Modifications not approved by the party responsible for compliance
could void the user's authority to operate the equipment.
*NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
*
Reorient or relocate the receiving antenna.
*
Increase the separation between the equipment and receiver.
*
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
outlet box
green/
green/
green/
bare
bare
bare
ground
ground
ground
black
black
(AC IN from
breaker box)
(wiring for wall control)
canopy
screw
page 6
wall
control
I
I
I
I
I
IV
II
V
VI
VI
I
green
black (OUT to fan)
black
(TO POWER supply)
12V battery
hanging bracket
canopy cover
dimmer
switch
plate