Real time clock
Six start times for defrost.
Setting of hours.
0=OFF
Six start times for defrost.
Setting of minutes.
0=OFF
Clock - Setting of hours
Clock - Setting of minutes
Clock - Setting of date
Clock - Setting of month
Clock - Setting of year
Miscellaneous
Delay of output signals after start-up
Input signal on DI1. Function:
0=not used. 1=status on DI1. 2=door function with alarm when open. 3=door alarm when
open. 4=defrost start (pulse-signal). 5=ext.main switch. 6=night operation. 7=change
reference (activate r40). 8=alarm function when closed. 9=alarm function when open.
10=case cleaning (pulse signal).
Network address
On/Off switch (Service Pin message)
IMPORTANT! o61 must be set prior to o04
Access code 1 (all settings)
Used sensor type (Pt /PTC/NTC)
Readout of software version
Display step = 0.5 (normal 0.1 at Pt sensor)
Max. hold time after coordinated defrost
Input signal on DI2. Function:
0=not used. 1=status on DI2. 2=door function with alarm when open. 3=door alarm
when open. 4=defrost start (pulse-signal). 5=ext. main switch. 6=night operation.
7=change reference (activate r40). 8=alarm function when closed. 9=alarm function
when open. 10=case cleaning (pulse signal). 11=not used. 12=defrost coordination.
Configuration of light function (relay 4)
1=ON during day operation. 2=ON / OFF via data communication. 3=ON follows
the DI-function, when DI is selected to door function or to door alarm
Activation of light relay (only if o38=2)
Rail heat On time during day operations
Rail heat On time during night operations
Rail heat period time (On time + Off time)
Case cleaning. 0=no case cleaning. 1=Fans only. 2=All output Off.
Selection of EL diagram. See overview page 2
Download a set of predetermined settings. See overview previous page.
Access code 2 (partly access)
Replace the controllers factory settings with the present settings
Readout of Unit runtime in days
Service Alarm request.
Days of operation (Unit runtime) before Service request alarm
Value = 0 disables function
Defines action when Condenser blocked alarm activates:
0=Function disabled. 1=Turn off Light, 2=Stop compressor. 3=Light and comp off,
4=Stop comp, Rail heat and light off. 5=Comp, Light and RH off
Period for counting condenser events before permanent stop
Number of condenser events within period before permanent stop
Value = 0 disables function
Service
Status codes are shown on page 5
Temperature measured with Sair sensor
Temperature measured with S5 sensor
Status on DI1 input. on/1=closed
Status on night operation (on or off ) 1=closed
Read the present regulation reference
Status on DI2 output. on/1=closed
Temperature measured with Sc sensor
Temperature shown on display
Status on relay for cooling
Status on relay for fan
Status on relay for defrost
Status on relay for rail heat
Status on relay for alarm
Status on relay for light
Status on relay for compressor 2
Status on relay for condenser fan
*) Can only be set when regulation is stopped (r12=0)
**) Can be controlled manually, but only when r12=-1
***) With access code 2 the access to these menus will be limited
4 | AN33481406482302-000201
1
2
3
4
t01-t06
t11-t16
***
t07
***
t08
***
t45
***
t46
***
t47
o01
o02
o03
o04
o05
o06
o08
o15
o16
o37
o38
o39
o41
o42
o43
***
o46
*
o61*
*
o62*
***
o64
o67
*
P48
P91
P92
P93
P94
S0-S34
u01
***
u09
u10
***
u13
u28
u37
U09
u56
**
u58
**
u59
**
u60
**
u61
**
u62
**
u63
**
u67
**
u71
5
0 hours
23 hours
0 hours
0 min.
59 min.
0 min.
0 hours
23 hours
0 hours
0 min.
59 min.
0 min.
1
31
1
1
12
1
0
99
0
0 s
600 s
5 s
0
10
0
0
240
0
OFF
ON
OFF
0
100
0
Pt
ntc
Pt
no
yes
no
0 min.
60 min.
20 min.
0
12
0
1
3
1
OFF
ON
OFF
0%
100%
100%
0%
100%
100%
6 min.
60 min.
10 min.
0
2
0
1
5
1
0
2
0
0
100
0
OFF
On
OFF
0 days
999 days
0 days
0 days
960 days
0 days
0
5
0
0 hours
96 hours
0 hours
0
50
0
© Danfoss | DCS (vt) | 2021.03