Descargar Imprimir esta página
Microlife MT16K1-PRO Manual Del Usuario

Microlife MT16K1-PRO Manual Del Usuario

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Digital Thermometer
Measuring Sensor Tip
This clinical digital electronic thermometer is for the
intermittent measurement and monitoring of human
adult and pediatric body temperatures; orally, rectally
and under the arm.
This thermometer IS intended to be used:
• For self-measurement/monitoring of human body
temperature whereas the person being measured may
be the user/operator of the device.
• Adults and pediatric
• With an optional Probe Cover (probe cover not mandatory)
This thermometer IS NOT intended for use with:
• Neonatal
GENERAL WARNINGS
• Please contact your physician in case of prolonged
fever as this requires medical attention, especially for
young children.
• Do NOT allow children to play with this device; it is not
a toy.
• Do NOT leave children unsupervised while taking their
temperature.
• Do NOT allow children to run or walk while taking their
temperature as the device could present a hazard.
• Do NOT dispose of the device or battery in fire; the
battery may explode.
• Do NOT attempt to recharge the battery.
• Do NOT open the thermometer as the battery is not
replaceable.
• Do NOT use a metal tool to remove batteries; doing so
may short circuit the terminals.
• Do NOT use the device if you think it is damaged or if
anything appears unusual.
• Batteries and electronic instruments must be disposed
of in accordance with the locally applicable regulations,
and not as domestic waste.
• Keep battery away from children. Harmful if swallowed.
• It is recommended that this digital thermometer be
checked for calibration every 2 years.
• This device contains sensitive electronics components.
Avoid strong electrical or electromagnetic fields in the
direct vicinity of the device (e.g., mobile telephones,
microwave ovens). These can lead to temporary im-
pairment of the measuring accuracy. Move the device
to another location if interference is determined and
maintain a minimum distance of 11 ft from such devices
when using this unit.
• Performance of this device may be degraded if:
• Used or stored outside the relevant specified
temperature and humidity range
• The device is exposed to mechanical shock
• The patient's temperature is lower than that of the ambient
• Do not store the unit under direct sunlight, at a high
temperature , or in high humidity or dust.
Turning on the Thermometer
To turn on the thermometer, press the ON/OFF button
1. Display should read "188.8" to confirm normal function.
2. Next, a measuring screen showing a «L» and a flashing
«°F» is displayed (at an ambient temperature of less
than 90°F ).
3 The thermometer is ready for use when the measuring
screen is displayed.
Function Test
The thermometer performs a self-test automatically each
time it is turned on. If a malfunction is detected, «ERR» will
appear on the display, and the thermometer will no longer
work. If this occurs, the thermometer must be replaced.
Using the Thermometer
Important: This
thermometer can be
used with or without a
probe cover. If a probe
cover is used, place it
over the measuring tip as
shown in the diagram.
If a Probe Cover is not used, cleaning should be done per
the instructions.
While a measurement is in progress, the current temper-
ature is displayed and the temperature symbol will blink
(symbol =°F). When the temperature symbol stops blink-
ing, the reading is complete (blinking stops when the
increase in temperature is less than 0.1 °F in 6 seconds).
To prolong the battery life, turn off the thermometer by
briefly pressing the ON/OFF button once the reading is
complete. Otherwise the thermometer will automatically
turn off after approximately 8 minutes.
Measuring Methods
ORAL USE: (for ages four and up)
• Do not drink hot or cold fluids,
exercise, smoke, or perform
other activities that will raise or
lower temperature readings
when compared to your normal,
average temperature. The mouth
should remain closed up to 5
minutes before taking a reading.
• Press the power button and when the measuring
screen is displayed (L°F), place the probe tip under the
tongue in the position shown by the check marks (see
diagram). Instruct children not to bite down on the probe.
• The peak temperature should be reached in approxi-
mately 60 seconds. Opening the mouth or improper
placement of the probe tip could result in a longer time
for a reading.
MT16K1-PRO-0920_5
Digital Thermometer
Digital Thermometer for
measuring body temperature.
Contents:
Digital Thermometer, Carrying Case,
English/Spanish Instructions
Follow instructions of use to
avoid hazards.
Made in China
Instructions for Model #MT16K1-PRO
LCD Display
UNDERARM (AXILLARY) USE:
• Wipe underarm with a dry towel.
• Place probe tip in armpit and bring arm down against
the body. The measuring sensor should be pointing
upward in the same direction as your body if possible.
• To receive more reliable
results we recommend to
measure temperature orally
or rectally. Approximate du-
ration for an axillary meas-
urement is 5 to 10 minutes.
RECTAL USE:
• Commonly used for babies, young children or when it is
difficult to take an oral or underarm temperature.
• After placing the probe cover on the thermometer,
lubricate with a water-soluble solution such as
lubricating jelly.
• Gently insert the probe tip no more than 1/2 inch or 1-2
cm into the rectum. Do not force the tip into the rectum
if resistance is encountered.
• Dispose of the used probe cover and wash the
thermometer as recommended.
• The peak temperature should be reached in approximately
60 seconds.
Cleaning
Clean thermometer before and after every use:
1. Clean sensor tip with 70% isopropyl alcohol. Wipe dry
with sterile cotton ball.
Battery Exhaustion
When the "▼" symbol (upside-down triangle) appears
on the right side of the display, the battery is exhausted
and the thermometer needs to be replaced.
Technical Specifications:
Thermometer type:
Measurement range:
Temp. < 90.0°F:
Temp. > 109.9°F:
Measurement accuracy:
Operating conditions:
Storage conditions:
Battery:
Product life:
Reference to standards:
This Device corresponds to the following requirements
and standards for electronic thermometers:
ASTM E 1112, EN 12470-3, IEC 60601-1, IEC 60601-1-2, IEC
60601-1-11.
Ingress Protection (IP67): Totally protected against dust
ingress, protected against the effect of immersion between
15cm and 1m.
Electromagnetic Compatibility: This device fulfills the
stipulations of the standard IEC 60601-1-2.
Limited Warranty
Your Digital Thermometer has a 2 year warranty by
Microlife USA Inc, against manufacturer defects for the
original purchaser only, from date of purchase.
The 2 year warranty applies to the thermometer. Batter-
ies and case are not covered by this warranty. There are
no user serviceable parts inside.
The warranty does not apply to consequential and inci-
dental damages, or damage caused by batteries, im-
proper handling, and accidents. Professional use, not
following the operating instructions, and alterations
made to the device or accessory by third parties, are
also not included in this warranty. Some states do not
allow the exclusion or limitation of incidental or conse-
quential damages, so the above limitation or exclusion
may not apply to you.
Microlife USA Inc will investigate your concern. A
product as defined by this warranty, determined to be
out of specification, will be replaced and shipped to you
at no cost. A product or accessory as defined by this
warranty, determined to be within specification, will be
returned to you with a report of findings, at no cost.
Please call customer service: 1-800-568-4147 regarding any
warranty concerns. We ask that you please
contact us before sending any product back in order to
better identify, and more quickly process, your concern.
This warranty gives you specific legal rights, and you
may also have other rights which vary from state to
state.
Test Protocol (for laboratory use only):
1. Place thermometer into waterbath. The tip of the
thermometer should be approximately 2cm below
the surface.
2. Wait for 10 seconds, then turn the thermometer on
by pressing the "On/Off" button. The thermometer
is now in standard mode.
3. When the measurement is completed, record the
temperature reading.
Type BF applied part
Distributed by:
Microlife USA
1617 Gulf to Bay Blvd, 2nd Fl.
Clearwater, FL 33755
Toll Free: 1-800-568-4147
ON/OFF Button
90.0°F~109.9°F.
display «L» for low (too low)
display «H» for high (too high)
50°F to 104 °F relative humidity
of 15 to 95% noncondensing
-13°F to 140°F relative humidity
of 15 to 95% noncondensing
1.5 V; LR 41, battery life
aprox. 2500 measurements
(using a new battery)
5 years
Actual
± 0.2°F

Publicidad

loading

Resumen de contenidos para Microlife MT16K1-PRO

  • Página 1 Your Digital Thermometer has a 2 year warranty by time it is turned on. If a malfunction is detected, «ERR» will Microlife USA Inc, against manufacturer defects for the appear on the display, and the thermometer will no longer original purchaser only, from date of purchase.
  • Página 2 0.1 °F en 6 segundos). Por favor llama al servicio al cliente de Microlife USA Para prolongar la duración de la batería, apague el ter- Inc.: 1-800-568-4147 para cualquier reclamo de garantía.