Cold Weather Operation - Ego Power+ BA1400T Manual Del Operador

Ocultar thumbs Ver también para BA1400T:
Tabla de contenido

Publicidad

OPERATION
EN
5-LED INDICATOR ON BATTERY PACK
This lithium-ion battery pack is equipped with a 5-LED
indicator, press the power button to display the charge
level or its working condition, the LED indicator will be
illuminated for 10 seconds
Battery charge
5-LED
level/Working
indicator
condition
80% ≤ Charge
level ≤ 100%
60% ≤ Charge
level <80%
40% ≤ Charge
level < 60%
20% ≤ Charge
level < 40%
10% ≤ Charge
level < 20%
Charge level <
10%
Low voltage
Over
temperature
BATTERY PROTECTION
The battery circuitry protects the battery pack from extreme
temperature, over-discharge, and over-charge. To protect
the battery from damage and prolong its life, the battery
pack circuitry will turn off the battery pack if it becomes
overloaded or if the temperature becomes too high during
use. This may happen in extremely high torque, binding,
and stalling situations. The battery pack will shut down with
power indicator flashing orange for 10s when its operating
temperature exceeds 70°C, and will begin normal operation
when it returns to 67°C.
6
56 VOLT BATTERY — BA1400T/BA2800T/BA4200T/BA5600T
Notice: A significantly reduced run time after fully charging
the battery pack indicates that the batteries are near the end
of their usable life and must be replaced.

COLD WEATHER OPERATION

This Lithium-Ion battery pack will provide optimal
performance in temperatures between 0°C and 40°C.
When the battery pack is very cold, it may "pulse" for the
first minute of use to warm itself. Put the battery pack on
Remarks
a tool and use the tool in a light application. After about a
minute, the battery pack will have warmed itself and will
operate normally.
5-LED shining green
WHEN TO CHARGE THE BATTERY PACK
NOTICE:
charged. Before using it the first time, fully charge the
4-LED shining green
battery pack.
NOTICE:
self-maintenance function to extend the battery life.
3-LED shining green
Depending on the battery charge, it will automatically
perform a self-discharge operation after one month of
storage. After this self-maintenance, the battery pack
2-LED shining green
will enter sleep mode and maintain 30% of its charge
capacity. If stored for a month or longer, fully recharge the
battery before the next use.
1-LED shining green
It is not necessary to run down the battery pack charge
before recharging. The Lithium-Ion battery can be
charged at any time and will not develop a "memory"
1-LED flashing red.
when charged after only a partial discharge. Use the
power indicator to determine when the battery pack
needs to be recharged.
5-LED flashing red.
The battery pack is nearly
HOW TO CHARGE THE BATTERY PACK
depleted and needs to be
charged immediately.
Follow the instructions in the Operator's Manual for the
EGO CH5500E Rapid Charger or CH2100E Charger.
5-LED shining red.
Cool the batter pack until
TO ATTACH AND DETACH THE BATTERY PACK
the temperature drops
Follow the instructions in the Operator's Manual for the
below 67°C.
individual EGO product.
MAINTENANCE
always remove the battery pack from the tool when
changing accessories, cleaning or performing any
maintenance.
replacement parts. Use of any other parts may create a
hazard or cause product damage.
Lithium-Ion battery packs are shipped partially
This battery pack is equipped with an advanced
WARNING:
To avoid serious personal injury,
WARNING:
When servicing, use only identical EGO

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ba2800tBa4200tBa5600t

Tabla de contenido