Installation
CAUTION: LAMP HOLDERS MUST BE NON-SHUNTED. POWER FLOWS THROUGH LED U BENT.
Note: LED U bent requires single end power only; wiring to one side of the xture is suf cient. Ensure lamp end
labeled "POWER THIS END" is installed to the live circuit.
DANGER -RISK OF ELECTRIC SHOCK-DISCONNECT POWER TO LIGHT FIXTURE BEFORE INSTALLATION.
Note: To replace uorescent tube lamp with LED U bent, the wiring must be installed according to these
instructions to ensure a complete and safe installation of the LED U bent.
1. Turn off the power to the light xture at the breaker panel before installation.
2 If retro tting an enclosed xture open the diffuser from the light xture.
3. Remove existing uorescent lamps. Please dispose or recycle these items properly in accordance with local
requirements as they contain mercury.
4. Open the wiring cover to expose the uorescent ballast.
Wiring diagram for U bent fluorescent lamp with electronic ballast (I)
Wiring diagram for U bent fluorescent lamp with electronic ballast (II)