ISSUE
Parts/accessories missing
Vacuum cleaner will not start
Dust discharging from exhaust
Loss of suction
Static shock
π
CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA
PAGE 8 OF 24

TROUBLESHOOTING

POSSIBLE CAUSE(S)
1.
Packed in tank
1.
No power at receptacle
2. Defective switch
3. Defective motor
1.
Filter not installed or installed
improperly
2. Filter damaged
3. Filter clogged or dust is
too fine
4.
Filter not functional
1.
Loose hose connection
2. Filter clogged
3. Full tank
4.
Hole in hose
1.
Dry environment
2. Relative humidity of air is low
1-800-295-5510
uline.com
CORRECTIVE ACTION
1. Check in tank.
1. Check for power.
2. Replace switch.
3. Replace motor.
1.
Properly install filter.
2. Replace filter.
3. Use more efficient filter.
4. Clean and replace filter.
1. Tighten hose connection.
2. Clean or replace filter.
3. Empty tank.
4. Replace hose.
1. Add moisture to air
(if practical, use a console or
installed humidifier).
2. This situation is temporary
and does not affect use of
vacuum cleaner.