Hansgrohe Ecostat 1001 SL 13241 Serie Instrucciones De Montaje página 9

Ocultar thumbs Ver también para Ecostat 1001 SL 13241 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
XXX = Colours
000 chrome
800 steel
810 satinox
Fault
Insufficient water
Crossflow, hot water is forced into
cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not corre-
spond with the temperature set
Temperature regulation not possible - MTC-thermo cartridge calcified
Shower or spout dripping
Instantaneous heater didn't work
with thermostat
English
Cause
- Supply pressure inadequate
- Filter are dirty (14)
- Shower filter seal dirty
- Backflow preventers dirty or
leaking
- Thermostat has not been ad-
justed
- Hot water temperature too low
- Dirt or sedaimentation on valve
seat, shut-off unit damaged
- Ecostop ring isn't removed
- Flow limiter in handshower isn't
removed
- Filter are dirty
- Non return valve didn't move
back
Remedy
- Check mains pressure
- Clean filter in front of the mixer
and on the MTC-thermo car-
tridge (14)
- Clean filter seal between shower
and hose
- Clean backflow preventers,
exchange if necessary
- Adjust thermostat
- Increase hot water temperature
to 42 °C to 65 °C
- Exchange MTC-thermo cartridge
- Clean or exchange shut-off unit
- Remove ecostop ring (12)
- Remove flow limiter
- Clean the filter/exchange filter
- Exchange non return valves


Publicidad

Tabla de contenido
loading

Tabla de contenido