Battery Test; System Test - Tool it NBT 200 Manual De Instrucciones

Ocultar thumbs Ver también para NBT 200:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
Translation of the original instructions
5- Connect the negative (black) terminal to the negative terminal of the battery.
Connect the positive terminal (red) to the positive terminal of the battery.

BATTERY TEST

1. The screen lights up and displays the battery voltage. Press the «ENTER»
key to continue.
2. Select the battery type (Standard liquid battery or Sealed battery: VRLA/
GEL/AGM) with the arrow buttons and click on «ENTER»‚ to confirm.
3. Select the standard (marked on the battery) with the arrow buttons and
click on «ENTER»‚ to confirm. (Standard : CA, MCA, DIN, IEC, EN, SAE)
4. Enter the starting current indicated on the battery («A») and confirm.
5. If the display shows «CHA», specify whether or not the battery is charged
with the arrows and confirm with «ENTER».
6. One of the results below is displayed.
• Battery test result
Résultat
BATTERIE OK
OK FOR RECHARGE
 CHARGE & TEST
 TO BE REPLACED
ERROR

SYSTEM TEST

1. The display shows the battery voltage XX.XX on screen. Press the «ENTER»
button.
2. Press the arrow buttons ▲\▼ to select the «SYST» system test and press
the «ENTER» button.
3. Power off all vehicle consumables, such as lights, air conditioning, radio,
etc. before turning on the engine.
5. The screen displays «CrAn», press the «ENTER» button to read the mini-
mum battery voltage.
6. Start the engine. The result is displayed
• Result of the start voltage test
Result
Green LED
Yellow LED
Red LED
1. Press «ENTER» to proceed to the load system test. The display shows
«CHar». Press «ENTER» to display the voltage.
2. Make sure to keep the car consumers (air conditioning, radio etc...) swit-
ched off.
3. Run the engine between 1200 and 1500 rpm.
• Load system test result (without consumers)
Result
Green LED
6
Screen display
Green light
XXXX (CCA value)
Green and yellow
XXXX (CCA Value)
Yellow and red
XXXX (CCA value)
Red light
XXXX (CCA value)
in red on the
screen
No problem detected. Unit operating normally.
Problem with the starting system. Check connections, cables
and the starter.
Check that the connections are good. If everything is properly
connected, replace the starter.
No problem detected. Normal operation of the alter-
nator.
NBT 200
The battery is operational.
Battery in good condition but
light
low state of charge.
Charge the battery and perform
the test again. If the result re-
light
mains the same, change the
battery.
The battery is nearing the end of
its life.
Replacement required.
The battery is higher than 1200
ERR
CCA (SAE) or a problem at the
cell level is found (short cir-
cuit...). Replace the battery.
Analysis
Analysis
EN
Analysis

Publicidad

Tabla de contenido
loading