Automatic power off:
No automatic power off:
Warm-up time for the sensor:
Shelf-life of the sensor:
Panel description:
1 = sensor (type LSXS4)
2 = protective cover of the sensor (type LS4000-SP)
3 = LED – display
4 = button for low sensitivity
5 = button for high sensitivity
6 = RESET - button
7 = display for battery status 8 = ON / OFF
9 = battery cover
10 = screw for battery cover
11 = AC power adapter connector 5V, and 0,5A
(adapter only as option at extra cost)
12= reference test bottle, this bottle allows you to test
whether your device is working correctly.
Approach the sensor and then the device should deflect
to minimum the middle of it. If not, please exchange the sensor LSXS4.
Attention: please never hold the device in the flow of gas as this leads to immediate defect of the
sensor.
Inserting batteries:
When the batteries need to be replaced the RED LED
in the middle of the panel element is illuminated.
Unscrew the screw of the battery cover and then
put the batteries correctly into place respecting polarity.
Close the battery cover again and slightly tighten the
screw for the battery cover.
LED display for the respective sensitivity settings
Base = basic setting
More = press High for higher sensitivity
Highest = highest setting for sensitivity
Sensitivity:
R1234YF,134A
Forming gas
R-404A, 407C, 410A 4g/year
approx. 10 minutes
press and hold the HI-button and device switch ON
Then continue working with the device normally
(continue leak detection run).
approx. 60 seconds
approx. 8.600 h
H
3g/year
1
2
3
4
7
8
9
M
15g/year
20g/year
5
6
1 0
L
30g/year
40g/year