Model 224XST
24VDC
To achieve electrical supervision:
224XST DC Beacon
1/2" conduit
Wire black to positive,
red to negative, and
green/yellow to earth
(ground).
The other red and
black pair should
be connected to next
224XST Beacon.
Junction box
Mounting the Device: Units come standard to mount 1/2" NPT threaded pipe. Model 225XST-N
must be mounted in a dome up position to resist water and debris accumulation and maintain the
NSF Certification.
To comply with NEC Section 300-14, which requires a minimum of 6" of free conductor at a junction, the pipe
used to join the unit to a splice box should be no longer than 10".
Wall mounting bracket (LHWB) is sold separately and is intended for use with models 224XST, 225XST and
225XST-I only. LHWB is not NSF Certified and incompatible for use with model 225XST-N.
Pipe Mount: Feed wires through pipe and turn clockwise to tighten. To prevent connection from loosening,
tighten fixture to a minimum of 5ft.-lbs. (6.8Nm) after threading onto pipe.
Testing and Operating: After installation, test the unit to verify operation and establish program for periodic
testing. Provide copy of instructions to all operating personnel.
Ordering Replacement Parts and Accessories: Consult product datasheet online for an updated list of
replacement parts. If product requires a part that is not available for purchase, your unit must be repaired or
replaced. The product's dome should be regularly inspected for scratches or chips and if damaged, it must be
replaced. A strap wrench (6" capacity) may be used to aid in dome removal.
Technical Assistance: Contact our technical support team at +1-708-587-3587 or
signalsupport@fedsig.com.
Repair Service: A return authorization is required. Contact your Authorized Distributor or Federal Signal
Customer Support. Defective products under warranty will be repaired or replaced at Federal Signal's
discretion. Lamp failures excluded.
Product Returns: Returns require authorization from Federal Signal. Contact your Authorized Distributor for
more information on our return policy or to request a return.
2645 Federal Signal Drive, University Park, Illinois 60484
Additional translations available at www.fedsig.com
Traducciones adicionales disponibles en www.fedsig.com
Customer Support 1-800-344-4634+1-708-534-4756, iordersup@fedsig.com
Technical Support 1-800-755-7621+1-708-587-3587, signalsupport@fedsig.com
Models 225XST, 225XST-I and 225XST-N
DC Models
Note: Conduit, wire nuts and junction box pictured are not supplied
AC Models
DC Beacon
1/2" conduit
Wire black to positive,
red to negative, and
green/yellow
to earth (ground)
Junction box
AC Beacon
1/2" conduit
Wire black to line
(L or L1)
white to neutral
(N or L2)
green/yellow to earth
(ground).
Junction box