Installation Instructions
LiteKeeper 16/32 Enclosure
Boîtier LiteKeeper 16/32
Recinto envolvente LiteKeeper tamaños 16 o 32
General Information
The Lighting Control System Enclosure is packaged
separately from the logic board to protect components
during shipping. This installation instruction pertains to
the installation of the enclosure for this unit. Please refer
to the installation instruction for your logic board for
information specific to the logic board installation.
The enclosure is available in two different sizes: 16 size
and 32 size. It can be configured with different relay types
as needed to achieve your lighting needs.
Getting Started
1.
Do not discard these installation instructions. Please
keep for future reference and operation information.
2.
The relay cards are protected by shrink-wrap. Leave
shrink-wrap in place until all drilling and metal work is
complete to protect against metal shards getting into
component circuitry.
3.
Always disconnect all power before wiring.
4.
Use only as intended and at the listed voltage.
5.
All installation service must be performed by qualified
personnel or service technicians.
6.
Install in accordance with National Electrical Code
and any other codes that may apply.
7 .
High Voltage is present inside the lighting enclosure.
Use extreme caution when performing maintenance
on this equipment. Failure to follow this warning and
proper safety procedures could result in severe injury
or death and/or damage to the equipment.
8.
Document all wiring that is terminated to the relays
so that the lighting control equipment can be properly
configured and programmed for operation.
Model # LK 16
Model # LK 32
Mounting in the Enclosure
1.
If the enclosure is a 32 size, remove the upper back
plate from the enclosure by using the 1/4 turn screws
provided. The proper operation of these screws is to
push in gently and turn 1/4 turn left until the screw
head is horizontal to release the catch mechanism.
Turning these screws more than 1/4 turn may cause
them to break.
2.
Choose a dry location convenient to the circuit
breaker panel.
3.
Mount the panel on a firm surface using pre-drilled
holes.
4.
Connect the enclosure to the circuit breaker panel
using conduit. The conduit punch hole cannot exceed
3 inches from the back of the enclosure. If this
measurement is exceeded, the logic board will not fit
properly inside the enclosure.
5.
Remove all cuttings and dirt before removing shrink-
wrap from the relay cards.
Make certain that high voltage and low voltage
N
ote:
wiring enters the enclosure separately. High
Voltage wiring should not be brought into the
enclosure through the bottom or bottom left corner
of the enclosure.
Low Voltage wiring can be brought into the enclosure
from the bottom or bottom left of the enclosure. If low
voltage wire must be brought into the cabinet from the
top section, there is a knockout reserved on the left side
which will allow conduit to be run from the top of the
enclosure into the low voltage wiring area.
INS #