Clearing a jam from the discharge area:
1.
Disconnect the tool from the air supply.
2.
Remove all fasteners from the tool (see "unloading the tool" section in this
manual).
3.
Loosen the 2 allen screws on the nose tip assembly with a 1/8" allen wrench
(included) (A).
4.
Remove the nose plate assembly by sliding it down towards the fastener
discharge area (B).
5.
Using a pliers, remove all jammed fasteners from the fastener feed area (C).
6.
Replace the nose plate assembly and slide it upwards towards the top of the
tool so that the curved area fits around the screws and then tighten the
screws.
7.
Make sure the contact safety trip mechanism moves freely.
8.
Reload the tool with fasteners (see "loading the tool" section in this manual).
9.
Reconnect the tool to the air supply.
Clearing a fastener jammed inside the tools magazine:
1.
Disconnect the tool from the air supply.
2.
Remove all fasteners from the tool (see "unloading the tool" section in this
manual).
3.
Remove all jammed fasteners.
4.
Reload the tool with fasteners (see "loading the tool" section in this manual).
5.
Make sure the contact safety trip mechanism moves freely.
6.
Reconnect the tool to the air supply.
Lubrication:
To maintain the maximum performance of the air tool, it must be lubricated each time it is used. Dust, dirt,
rust and oil residue will build up inside the tool and reduce the performance. An in-line oiler is recommended for
proper automatic tool lubrication (See Figure 1). If an in-line oiler is not available, the tool can be lubricated manu-
ally through the inlet port (see Figure 5).
1.
Disconnect the tool from the air supply.
2.
Remove all fasteners from the tool (see "unloading the tool" section in
this manual).
3.
Turn the tool so that the air inlet port is facing up.
4.
Place 4-5 drops of air tool oil or SAE10 nondetergent oil into the air
inlet port. Note: Never use detergent oil or additives in the tool,
these will cause accelerated wear to the seals in the tool. Do not
over lubricate.
5.
Clean the handle and surface of the tool of any oil residue.
6.
Reload the tool with fasteners (see "loading the tool" section in this
manual).
7.
Reconnect the tool to the air supply.
Cleaning the tool:
1.
Disconnect the tool from the air supply.
2.
Wipe the tool clean daily. Use non-flammable cleaning solutions only if necessary.
Air Inlet
Recommended Hose Size
Maximum Working Pressure
Operating Pressure
USER-MAINTENANCE INSTRUCTIONS
USER-MAINTENANCE INSTRUCTIONS
Always disconnect the tool from the air supply before
making adjustments, doing tool maintenance and
clearing jams to to reduce the risk of injury to persons.
T
OOL
T
OOL
SPECIFICA
TIONS
SPECIFICA
TIONS
1/4" NPT (Female)
3/8"
100 PSI
60-100 PSI
6 - ENG
Figure 5