Cleaning of the water channel
To clean the water channel, remove the drain plug on the back of the unit and drain the
water into the water channel. If the water in your area is very hard, mineral deposits can
accumulate on the nebulizer plate and affect nebulizer performance. Mix water with a
dash of vinegar and apply to the plate. Allow the mixture to work for 2-5 minutes and
then clean the surface with a damp cloth.
Note: Do not clean the water channel under running water to prevent water from
entering the interior of the unit and damaging electrical components.
After cleaning
• After cleaning, replace the mist eliminator cover in its original position and rotate
the clamp on the cover to clamp the cover to the connector and ensure that the float
is mounted in the connector in its original position. Then reinsert the drain plug and
the water tank.
• After cleaning, check that all parts are correctly assembled before putting the fan
back into operation.
• If you will not be using the unit for a long time, remove the batteries from the remote
control and store the unit in a clean, dry place.