Descargar Imprimir esta página

Balluff BTL5-S1 Serie Instrucciones Breves página 3

Transductor de desplazamiento micropulse
Ocultar thumbs Ver también para BTL5-S1 Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL5-S1_ _(B)-M_ _ _ _-A/B/Y/Z-(SA244)-S32/KA_ _
Micropulse Linear Transducer – Rod Style
EC Directive 89/336/EEC (EMC Directive) and EMC Law
Generic standards: EN 61000-6-4 (Emission), EN 61000-6-2 (Noise Immunity)
Emission tests: RF emission EN 55011 Group 1, Class A
Proper application
The BTL5 Micropulse transducer is
intended to be installed in a ma-
chine or system. Together with a
controller (PLC) or a master it com-
prises a position measuring sys-
tem and may only be used for this
purpose.
Installation
Ensure that no strong
electrical or magnetic
fields are present in the
immediate vicinity of the trans-
ducer.
The contact surface of the trans-
ducer must be completely con-
tacted by the mounting surface.
The O-ring supplied must make a
perfect pressure seal. To achieve
secure mounting, use the proper
nut for the mounting thread. When
tightening the nut, do not exceed a
tightening torque of 100 Nm.
For horizontal mounting of trans-
ducer with stroke lengths greater
than 500 mm, the pressure tube
should be supported or attached
at its end. When installing in a
hydraulic cylinder, do not allow the
magnet ring to rub against the
pressure tube. The bore diameter
in the piston and cylinder rod
should be at least 13 mm.
Mounting
B: 30 -1 mm
surface
Z: 2" - 0.04"
BTL5...B/Z-S32
Mounting
surface
BTL5...A/Y-...
Wiring
System and control cabi-
net must be at the same
ground potential.
Pin
BTL5-S1_ _...S32
Interface signals
1
+Clk
2
+Data
3
–Clk
4
do not connect!
5
–Data
Supply voltage (external)
6
GND
7
+24 V
8
do not connect!
Colors
Interface signals
YE yellow
PK pink
GY gray
GN green
Supply voltage (external)
BU blue
BN brown
WH white
BKS Connector,
View of solder end
of connector body
BKS-S32M-00
or BKS-S33M-00
Nominal length =
measuring range
Magnet
Thread size:
B: M18×1.5
Z: 3/4"-16UNF
A: 30 -1 mm
Y: 2" - 0.04"
Magnet
Thread size:
A: M18×1.5
Y: 3/4"-16UNF
BTL5-S1_ _...-KA_ _
+Clk
–Clk
+Data
–Data
GND
+24 V
do not connect!
Damping zone
UL authorization
File No.
E227256
Startup
Observe all relevant safety regula-
tions!
Check connections: Components
can be damaged by improper con-
nections and overvoltage. Verify all
connections before applying power!
Turning on the system: Note that
the system may execute uncon-
trolled movements when the trans-
ducer is part of a closed-loop sys-
tem whose parameters have not
yet been set. Therefore make sure
that no hazards could result from
these situations.
Check functionality: The function-
ality of the transducer system and
all its associated components
should be regularly checked and
recorded. In particular, steps must
be taken to ensure that should the
transducer system become defec-
tive no hazards to persons or prop-
erty can result.
Fault conditions: When there is
evidence that the transducer sys-
tem is not operating properly, it
should be taken out of service and
guarded against unauthorized use.
User's Manual
A detailed user's manual can be ob-
tained on the Internet at
www.balluff.de using the link
Position Sensors, Micropulse Trans-
ducers, User's Manuals ..... E-mail
requests can be made to
balluff@balluff.de
unusable area
not included
english
1

Publicidad