The Maxeon Solar Technologies Limited Warranty for PV Modules is contingent 
upon modules being mounted in accordance with the requirements described in 
this section. 
 
5.1 Site Considerations      
AC Module should only be mounted in locations that meet the following 
requirements: 
 
Maximum Altitude: AC Modules can be installed in locations with a maximum 
of 2000 meter altitude. 
 
Operating Temperature: AC Modules must be mounted in environments that 
ensure that the modules will operate within the following maximum and 
minimum temperatures:   
Max. Operating Cell Temp. 
Max. Operating microinverter Temp. 
Max. AC Module Ambient Temp. 
Min. AC Module Operating Temp. 
 
Design  Strength:  AC  Modules  are  designed  to  meet  a  maximum  positive  (or 
upward, e.g. wind) and negative (or downward, e.g. static load) design pressure 
when mounted in the mounting configurations specified in Table 1 and 2 for the 
details  on  load  ratings  and  mounting  locations.  AC  Modules  have  also  been 
evaluated to IEC 61215 for a positive or negative design load of 3600 Pa with a 
1.5 Safety Factor.  
 
When mounting modules in snow‐prone or high‐wind environments, special care 
should be taken to mount the modules in a manner that provides sufficient design 
strength while meeting local code requirements. 
 
Important! 
The  following  image  and  tables  show  where  to  mount  in  module 
frame  and  the  allowable  load  ratings  corresponding  to  the  mounting  zones 
chosen. To use the tables, identify the two mounting zones in which you wish to 
mount. You may choose to mount at any location in zones A, B, and C, as long as 
the mounting points are symmetric about one axis of the module. Identify the 
combination of mounting zones you have chosen in the table and then refer to 
the  corresponding  load  rating.  Note  also  that  load  ratings  are  different  for 
modules supported by rails; versus systems that attach modules underneath the 
module frame or without rail support. 
 
Fig.1 With Rail Support 
                                  ©2021 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this document are subject to change without notice.     
+85°C  
+ 60°C 
+50°C 
−40°C 
Fig.2 Without Rail Support
 
Table 1. Test Load Ratings 
Test Load 
FOS=1.1 
Mounting 
Mounting 
Zone 1 
Zone 2 
*
Without Rail support means end mounted in long or short side frame. See Figure 2 
 
Table 2. Design Load Ratings 
Design Load 
FOS=1.5 
Mounting 
Mounting 
Zone 1 
Zone 2 
*
Without Rail support means end mounted in long or short side frame. See Figure 2 
 
Additional Authorized Operating Environments:  
Modules can be mounted in the following aggressive environment according to 
the test limits mentioned below: 
Salt mist corrosion testing: IEC 61701 Severity 6 
 
Ammonia Corrosion Resistance: IEC 62716 Concentration: 6,667 ppm 
 
Excluded Operating Environments 
Certain  operating  environments  are  not  recommended  for  Maxeon  Solar  AC 
modules,  and  are  excluded  from  the  Maxeon  Solar  Technologies  Limited 
Warranty for these modules. Maxeon's modules should not be mounted a site 
where  it  may  be  subject  to  direct  contact  with  salt  water,  or  other  aggressive 
environment. Maxeon's modules should not be installed near flammable liquids, 
gases, or locations with hazardous materials; or moving vehicles of any type. 
 
MAXEON SOLAR TECHNOLOGIES, LTD. 
Load Rating (Pa) 
Bolt 
Rail 
w/o Rail 
Rail 
Supported 
Support* 
Supported 
Wind (up and down)/ Snow (down) 
5400/9000 
5400/5400 
4100/8100 
4200/4200 
4200/3600 
2600/3600 
3000/4500 
3000/3000 
2400/3600 
2600/4200 
2400/2400 
2400/2400 
3000/4500 
3000/3000 
2400/3600 
DO NOT MOUNT 
Load Rating (Pa)  
Bolt 
Rail 
w/o Rail 
Rail 
Supported 
Support* 
Supported 
Wind (up and down)/ Snow (down) 
3600/6000 
3600/3600 
2700/5400 
2800/2800 
2800/2400 
1700/1600 
2000/3000 
2000/2000 
1600/2400 
1700/2800 
1600/1600 
1600/1600 
2000/3000 
2000/2000 
1600/2400 
DO NOT MOUNT 
 
 
537620 Rev.C 
 
Top Clamp 
w/o Rail 
Support* 
3600/5400 
2400/2400 
2400/2400 
2400/2400 
2400/2400 
Top Clamp 
w/o Rail 
Support* 
2400/3600 
1600/1600 
1600/1600 
1600/1600 
1600/1600 
 
   5