Würth WDM 30 Manual De Instrucciones página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Würth WDM30.book Page 12 Wednesday, December 9, 2009 4:43 PM
Causes:
Strongly reflecting targets deflect the laser
beam and cause measuring errors.
Non-reflecting, dark surfaces increase the
measuring time.
For constantly high-quality measurements
– Perform control measurements periodically.
– Perform control measurements before and
after important measurements.
Switching on/off
– Switch on the device by pressing key 4
briefly.
The device shows the battery symbol until
another key is pressed.
– Switch off the device by holding key 6 for
several seconds.
If no key is pressed for 180 seconds, the device
switches off automatically.
Clear key
– Undo the most recent action by pressing key
6 briefly.
Adjusting the measuring plane
See drawing F - H:
Rear measuring plane is the standard setting.
– For measurement from front edge, press key
7 briefly.
– For measurement from rear edge, press key
7 briefly again.
Unit setting
Metric system is the standard setting.
– To change the unit, hold key 7 for several
seconds.
With every keypress, the device switches to the
next unit.
Possible units:
meters with mm display
feet inch fractional
summary row up to 1/16 inch
second row up to 1/8 inch
inch fractional
summary row up to 1/16 inch
second row up to 1/8 inch
12/136
Measuring
Measuring single distances
– Press key 4 briefly.
– Aim active laser at target area.
– Press key 4 briefly.
The device measures the distance.
The device displays the result immediately.
Continuous measuring
See drawing J:
This function enables distances to be staked
out.
– Hold key 4 for several seconds.
Continuous measuring starts.
– Press key 4 briefly.
Continuous measuring stops.
The value last measured appears in the
summary row.
Functions
Area
See drawing I:
– Press key 8 once.
The area symbol appears on the display.
– Press key 4 and measure the first distance
(e.g. length).
– Press key 4 and measure the second distance
(e.g. width).
The device displays the result in the summary
row and the respective measured distance to
the next measurement in the second row.
Room volume
– Press key 5 once.
The volume symbol appears on the display.
– Press key 4 and measure the first distance
(e.g. length).
– Press key 4 and measure the second distance
(e.g. width).
– Press key 4 and measure the third distance
(e.g. height).
The device displays the result in the summary
row and the respective measured distance to
the next measurement in the second row.

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido