Data Management; Recall The Records - Salter BPA-9301-EU Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
Tips:
1. There are 3 users in total. Each user has 60
records,except user Guest.
2. You can press "
" button at any time to stop
measuring during the process of measurement.
3. If the measurement result is out of the measurement
range (SYS: 60mmHg to 230mmHg; or DIA: 40mmHg to
130mmHg;or Pulse: 40-199 pulse/minute), the LCD will
display "out".
4. If an irregular heartbeat was detected during the
reading, the irregular heartbeat detector indicator will
appear on the display. See page 22 for more information
on the irregular heartbeat detector feature.
5. If a motion was detected during the reading, the motion
indicator will appear on the display. It can affect the
accuracy of the measurement.
6. There isn't any user icon shown on the display during
the process of measurement when you select user
"Guest". After each measurement, the device will turn
off automatically if there is no operation. However, the
measurement result won't be stored and transmitted .

DATA MANAGEMENT

Recall the Records

1. When the monitor is off,
please press " " button
to show the average value
of the latest three records.
(Note: If the records are less
than 3 groups, the LCD will
display the recent record
instead. Take user 1 for
example.)
2. Press " " button or " " button to get the records you
want.
The current no. is
The corresponding
no.2. Seven records
date is December 1st
in total
The record number, date and
time of the measurement
records will display
alternately.
3. If you want to check another
user's records, press "
button to turn off the monitor
when the blood pressure
monitor is in the memory
mode. Press and hold
" " button to enter into
the electing user ID mode, press
" " button again to select the user ID among user 1, user
2 and Guest., press " " button to confirm the user ID , then
press " " button to check the selected user's measurement
records.
4. Press the "
" button to power off, otherwise it will
turn off within 1 minute.
CAUTION
The most recent record (1) is shown first. Each new
measurement is assigned to the first (1) record. All other
records are pushed back one digit (e.g., 2 becomes 3, and
so on), and the last record (60) is dropped from the list.
The measurement results of user Guest won't be stored in
the blood pressure monitor, so you can't review any data
of user Guest.