GB
3.0 CONTROLS: POSITION AND FUNCTIONS
3.1
FRONT PANEL - REAR PANEL
Figure 1.
2
3
6
5 5
1.
Connect the earth lead to the work piece to the negative terminal (-) (Ref. 6
- Fig. 1 page 3)
2.
Connect the torch lead to the positive terminal (+) Ref. 5 (Fig. 1 page 6).
Ensure that these connections are well tightened to avoid power loss and ove-
rheating.
3.
Use control knob Ref. 2 - Fig. 1 page 3) to regulate welding current.
4.
Illuminated switch Ref. 1 - Fig. 1 page 3) must be ON (lamp light) before
welding operations can be started.
5.
Illumination of the yellow LED Ref. 3 - Fig. 1 page 3) on the front panel
indicates a fault which prevents the equipment from functioning.
The yellow LED indicates two fault types:
a.
overheating caused by an excessively intense duty cycle. In this case, stop
welding and leave the power source switched on until the LED switches off.
✍
CONTROLS: POSITION AND FUNCTIONS
4.0 MAINTENANCE
during severe conditions.
Every three (3) months, perform the operations below:
1
a.
Replace unreadable labels.
b.
Clean and tighten weld teminals.
c.
Replace damaged gas hose.
d.
Repair or replace cracked cables and cords.
Every six (6) months, perform the operation below:
a.
Blow out the inside of the unit. Increase frequency of cleaning when opera-
ting in dirty or dusty conditions.
(GB) 3
Disconnect power before maintenance. Service more often
GB