International Travel; Introduction; Important Parts Of Your 7314 Series Devilbiss Suction Unit; Accessory/Replacement Items - DeVilbiss Vacu-Aide 7314 Serie Guía De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
3.
Keep the power cord away from heated surfaces.
4.
Never use while drowsy or asleep.
5.
Do not cover the unit or the AC to DC adapter while power is applied.
6.
Never operate this product if
a.
It has a damaged power cord or plug.
b.
It is not working properly.
c.
It has been dropped or damaged.
d.
It has been dropped into water.
Instead return the product to an authorized DeVilbiss Healthcare service center for examination and repair.
DANGER
The DeVilbiss Suction Unit is a vacuum suction device designed for the collection of nonflammable fluid materials in medical applications only. Improper use
during medical applications can cause injury or death. For all medical applications:
1.
All suctioning should be done in strict accordance with appropriate procedures that have been established by a licensed medical authority.
2.
Some attachments or accessories may not fit the tubing supplied. All attachments or accessories should be checked prior to use to assure proper fit.
INTERNATIONAL TRAVEL
The 7314 series is equipped with an AC to DC adapter allowing operation on any AC voltage (100-240 VAC, 50/60 Hz). However the correct power cord must be used to
connect to adaptable wall power.
NOTE– Check power cord for adaptability before using.

INTRODUCTION

Your DeVilbiss Suction Unit is a compact medical suctioning device which has been designed for reliable, portable operation. Following the recommended operating and
maintenance procedures outlined in this instruction guide will maximize the life of this product.
Intended Use Statement
The device is to be used to remove fluids from the airway or respiratory support system and infectious materials from wounds. The device creates a negative pressure
(vacuum) that draws fluids through disposable tubing that is connected to a collection container. The fluids are trapped in the collection container for proper disposal. It is for
use on the order of a physician only.
IMPORTANT PARTS OF YOUR 7314 SERIES DEVILbISS SUCTION UNIT
1.
Vacuum gauge
2.
Vacuum regulator knob
3.
6' patient tubing
4.
Tubing connector
5.
800 ml disposable container with lid (float shut off incorporated into lid) and filter cartridge
6.
Filter cartridge with 4
" tubing
3/8
7.
DC power input (on side)
8.
Power switch
9.
LED power lights
AC to DC adapter (not shown)
DC power cord (not shown)
Internal rechargeable battery (not shown)
Carrying case (not shown)
ACCESSORY/REPLACEMENT ITEMS
The following items can be purchased separately as accessories or replacement items for your 7314 Series DeVilbiss Suction Unit:
Description
6' patient tubing
12V DC power cord (1 each)
800 ml disposable container with filter cartridge and 4
AC to DC adapter/charger (see Specifications for manufacturer information)
Carrying case
Filter cartridge (12 pack)
Collection Container Kit (Filter cartridge, 800 ml container, 4
package)
NOTE– The use of electrical cables and accessories other than those specified in this manual or referenced documents may result in increased electromagnetic emissions
from the product or decreased electromagnetic immunity of the product.
A-7314
Part No.
6305D-611 Power cord for US
7304D-619 Power cord for Continental Europe
7305D-632 Power cord for UK
" tubing (48 each)
3/8
7314P-613 Power cord for Australia
7314D-606 Power cord for Japan
7305D-635 Power cord package (Europe, UK, Australia cords)
3/8
" and 6' tubing
7305D-633
9
8
7
6
5
Description
1
2
3
4
Part No.
DV51D-606
DV51D-607
DV51D-608
DV51D-609
DV51D-613
DV51D-611
EN - 3

Publicidad

Tabla de contenido
loading

Tabla de contenido