ACTIVATED CHARCOAL FILTER (RECIRCULATION VERSION)
The fi lter is not washable and cannot be regenerated. It must be replaced when led S1 fl ashes or
at least every 4 months. The alarm signal will only light up when the extractor motor is switched
on.
Alarm signal activation
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at
a later date. Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power sup-
ply.
• Restore the connection by pressing and holding T1.
• Release the button. All fi ve LEDs are turned on.
• Within 3 seconds press T1 until LEDs T1 and T4 fl ash in confi rmation:
-
LED fl ashes twice - Activated charcoal fi lter saturation alarm ENABLED.
-
LED fl ashes once - Activated charcoal fi lter saturation alarm DISABLED.
REPLACING CHARCOAL FILTERS
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the leds
start to fl ash.
Replacing the Filter
• Pull the Comfort Panel to open it.
• Remove the metal grease fi lters
• Remove the saturated activated carbon fi lter by releas-
ing the fi xing hooks
• Fit the new fi lter by hooking it into its seating
• Replace the metal grease fi lters.
LIGHT REPLACEMENT
20 W halogen light.
• Extract the lamp from the lamp holder by pulling
gently.
• Replace with another of the same type, making sure
that the two pins are properly inserted in the lamp
holder socket holes.