Long term storage ranges
Storage/transport temperature:
Humidity:
Battery:
Pressure:
This infrared thermometer meets requirements established in ASTM Standard E
1965-98 for the thermometer system. Full responsibility for the conformance of the
product to the standard is assumed by Kaz USA, Inc., 250 Turnpike Rd.,
Southborough, MA 01772, USA.
ASTM laboratory accuracy requirements for the thermometer only in the display
range of 96.8 °F to 102.2 °F (36 °C to 39 °C) for infrared thermometers is ± 0.4 °F
(± 0.2 °C), whereas for mercury-in-glass and electronic thermometers, the
requirement per ASTM Standards E 667-86 and E 1112-86 is ± 0.2 °F ( ± 0.1 °C).
This device conforms to the following standards:
IEC 60601-1:2006 Medical electrical equipment. General requirements for basic
safety and essential performance
ISO 80601-2-56 Particular requirements for basic safety and essential
performance of clinical thermometers for body temperature measurement
ASTM 1965E – ASTM Standard for Infrared Clinical Thermometers
EN 12470-5: 2003 «Clinical thermometers» – Part 3: Performance of compact
electrical thermometers (non-predictive and predictive) with maximum device.
IEC 60601-1-2: General requirements for basic safety and essential performance
Collateral Standard: Electromagnetic compatibility –
Requirement and tests
NOTE: Do not use this device in the presence of electromagnetic or other
interference outside the normal range specified in IEC 60601-1-2.
EN 980: 2008 Symbols for use in labeling of medical devices.
EN 1041: 2008 Information supplied by the manufacturer of medical devices.
EN 60601-1-11: 2010 Medical electrical equipment -- Part 1-11: General
requirements for basic safety and essential performance -- Collateral standard:
Requirements for medical electrical equipment and medical electrical systems
used in the home healthcare environment.
14
–13 °F to 140 °F (–25 °C to 60 °C)
15–95% non condensing
(2) AA Batteries - at least 1000
measurements
700-1060hPA (0.7-1.06 atm)
140 F
13
F
TYPE BF EQUIPMENT
Internally Powered ME Equipment
Continuous Operation
IP20: Protected against solid foreign objects of 12.5 mm diameter and greater.
MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC.
For detailed description of EMC requirements please contact Consumer Relations.
Portable and mobile RF communications equipment can affect MEDICAL
ELECTRICAL EQUIPMENT.
1. Dinarello CA, Porat R. Fever and hyperthermia. In: Fauci AS, Braunwald E, Hauser SL, Longo DL,
Loscalzo J, editors. Harrison's Internal Medicine. 17th ed. New York, NY: McGraw Hill Medical; 2008.
American College of Emergency Physicians. Clinical policy for children younger than 3 years presenting
to the emergency department with fever. Ann Emerg Med 2003;43(4):530-43.
Byington CL, Rittichier KK, Bassett KE et al. Serious bacterial infections in febrile infants younger than 90
days of age: the importance of ampicillin-resistant pathogens. Pediatrics 2003 May;111(5 Pt 1):964-8.
High KP, Bradley SF, Gravenstein S et al. Clinical practice guideline for the evaluation of fever and
infection in older adult residents of long-term care facilities: 2008 update by the Infectious Diseases
Society of America. J Am Geriatr Soc 2009 March;57(3):375-94.
Fox RH, Woodward PM, Exton-Smith AN, Green MF, Donnison DV, Wicks MH. Body temperatures in the
elderly: a national study of physiological, social, and environmental conditions. Br Med J 1973 January
27;1(5847):200-6.
Holt RIG, Cockram C, Flyvbjerg A, Goldstein,BJ. Textbook of Diabetes."Wiley-Blackwell; 2010
Doan T., Melvold R., Viselli S., Waltenbaugh C. Lippincott's Illustrated Reviews: Immunology, Second
Edition. Lippincott Williams & Wilkins; 2013
Non-Life Support Equipment Separation Distance Calculation
(3Vrms / 3V/m compliance)
Separation distance according to frequency of transmitter (m)
150 kHz to 80 MHz in
Rated maximum output
ISM bands
3,5
power of transmitter (W)
d = [
] P
V
1
0.01
0.12
0.1
0.37
1
1.17
10
3.69
100
11.67
80 MHz to 800
800 MHz to 2.5 GHz
MHz
3,5
7
d = [
] P
d = [
] P
E
E
1
1
0.12
0.23
0.37
0.74
1.17
2.33
3.69
7.38
11.67
23.33
15