20. Window seal plate assembly
21. Retaining screw
22. Wedging block for upper filter
23. Wedging block for lower filter
ASSEMBLING
Before first use, assembly the device as below:
1. The device should be placed on a flat surface. The distance to wall or other objects shall be least 50 cm to not limit air flow – look at
picture 6. Do not install and use the device in the bathroom or other high humid environments.
2. Install the window sealing plate assembly (20):
a) Half open the window, and mount the window sealing plate assembly (20) to the window (as shown on picture 5); the assembly (20) can
be placed in horizontal and vertical direction.
b) Pull various components of the window sealing plate assembly open, adjust opening distance to bring both ends of the assembly into
contact with the window frame, and fix components of the assembly.
3. Elongate the exhaust pipe (19) and snap the flat end of the heat pipe joints into the elliptical hole of the window sealing plate assembly
(as shown on picture 6).
Notes: 1. the flat end of the exhaust pipe joints must be snapped into place.
4. The length of the exhaust hose shall be 280~1,500mm, it cannot be distorted nor has substantial turning (greater than 45°). Exhaust
must be unobstructed; otherwise it may cause overheating. Do not use extension tubes or replace it with other different hoses, or this may
cause a malfunction.
DEVICE OPERATION
After connecting the device to the mains, the buzzer will play power-on music, it will go into standby mode and will display the present
ambient temperature.
1. To turn on or off the device, press the button (13).
2. Press the button (12) to select one of the available modes: COOL -> FAN -> DRY
3. In the COOL mode, set the temperature using the UP / DOWN buttons (11). It is not available in fan and dehumidification mode.)
4. During COOL or FAN modes use FAN button (10) to set the fan speed: STRONG (F3), MEDIUM (F2), WEAK (F1). But wind speed
operation is limited by anti-cold conditions, under certain conditions, it may not run according to the set wind speed. In DRY mode fan is
automatically set to level WEAK.
5. When the device is turned off it can be turned on with a delay by pressing the TIMER button (9). Press the UP / DOWN buttons (11) to
set the time for the device to be activated by selecting the time in the range of 1-24 hours. When the device is turned on it can be turned off
with delay by pressing the TIMER button (9). Press the UP / DOWN buttons (11) to set the time for the device to be switched off by
selecting the time in the range of 1-24 hours.
6. By pressing simultaneously the UP button (11) and FAN button (10) or by pressing the button SLEEP (17) on remote control the device
can be switched to sleep mode. The device will then operate quietly in the energy-saving mode. This function is only available in COOL
mode, not available in FAN and DRY modes.
7. The units (℃ <-> ℉) of required room temperature can be changed by pressing button (16) on remote control or simultaneously press
both buttons up key (11) and down key (11) to switch between Celsius (℃) and Fahrenheit (℉).
8. Press the button (15) to start the air oscillation, the blinds will move vertically. Press it again to stop air oscillation.
DRAINAGE INSTRUCTIONS
MANUAL DRAINAGE: When water in the water pan exceeds the warning level, the device will automatically sound an alarm and the LCD
display (14) area will show "FL". Also the FULL water control lamp (18) will light up. Then turn off the device and remove the plug from the