The following manual and guides were carefully prepared by the SilverStone engineering team to help you maximize the potential of your SilverStone product. Please keep this manual for future reference when upgrading or performing maintenance on your system. A copy of this manual can also...
SATA and SAS interfaces for increased compatibly with nearly all modern hard drives or SSDs. With a size that is nearly identical to most ATX mid towers, the space-saving CS380 is perfect for anyone looking to build a powerful NAS for home or office.
Case Storage CS380 Disassemble Chart RIGHT SIDE PANEL 12025 FAN LEFT SIDE PANEL 5.25” DRIVE BAY X2 POWER SW RESET SW USB 3.0 X2 + SPK + MIC DRIVE TRAY x8 12025 FAN X2 PICTURE ITEM PURPOSE SECURE 5.25" DRIVE SCREW-P/W-M3 SECURE MOTHERBOARD/3.5"...
Case Storage CS380 Front panel function guide Power button lock Open Locked The front door contains a power button lock. When the power button lock is locked, you will disable the power button on the front door, the only way to press the power button is by opening the front door again.
Case Storage CS380 Installation Chart Before you begin, please make sure that you have all components collected check that all components do not have compatibility problems with each other or with the case if possible, assemble the components outside the case first to make sure they are working...
Página 9
Case Storage CS380 Installation Chart Install power supply into the case Bauen Sie das Netzteil ins Gehäuse ein Installez la source d’alimentation dans le châssis Instale la fuente de alimentación en la carcasa Installazione dell’alimentatore nel case Установите в корпус блок питания...
Página 10
Case Storage CS380 Installation Chart Insert the I/O shield included with your motherboard Installieren Sie das hintere I/O-Blech im Gehäuse Installez la plaque arrière de la carte mère dans le boîtier Instale la placa trasera de E/S de la placa base en la carcasa Installare la placca I/O della scheda madre nella sede preposta Установите...
Página 11
Case Storage CS380 Installation Chart Insert standoffs as required by your motherboard in corresponding mounting holes, then install motherboard Stecken Sie die Abstandshalter wie für Ihr Motherboard erforderlich in die entsprechenden Befestigungsbohrungen. Installieren Sie dann das Motherboard Insérez les entretoises comme requis par votre carte mère dans les trous de montage correspondant, puis installez la carte mère Inserte los soportes según sea necesario para su placa base en los agujeros de montaje correspondientes, luego instale la placa base...
Página 12
Case Storage CS380 Installation Chart We recommend that you start cable manage now and connect cables such as the ATX 24pin, front I/O connectors, and any other connectors from front panel devices Wir empfehlen, jetzt mit dem Verlegen der Kabel zu beginnen und die 24-poligen ATX-, Front-I/O- und sämtliche weiteren Kabel von Geräten an der Frontblende anzuschließen...
Página 13
Case Storage CS380 Installation Chart Remove the 5.25" drive bay covers to install required 5.25" devices Dem Sie die Abdeckung der 5,25-Zoll-Laufwerkschächte ab, installieren Sie die gewünschten 5,25-Zoll-Geräte Retirez les caches des baies 5,25" pour installer vos appareils Quite las cubiertas para bahía de dispositivos de 5,25" para instalar los dispositivos de 5,25" necesarios Per installare le necessarie periferiche da 5,25", rimuovere il cover del bay da 5,25"...
Página 14
Case Storage CS380 Installation Chart Remove hot-swap trays and install 3.5" or 2.5" drives as needed, secure with screws then reinstall back into the drive cage Entfernen Sie die Hot-Swapping-Einsätze und installieren Sie wie erforderlich 3,5- oder 2,5-Zoll-Laufwerke; befestigen Sie sie mit Schrauben und installieren Sie die Einsätze wieder im Käfig...
Página 15
Case Storage CS380 Installation Chart Connect all cables for drives as needed including ones installed in 5.25" bay and the backplane Schließen Sie wie erforderlich alle Kabel für die Laufwerke an, einschließlich derer im 5,25-Zoll-Schacht und an der Backplane Connectez tous les câbles pour les lecteurs selon le besoin, y compris ceux installés dans la baie 5,25" et le fond de panier Conecte todos los cables para dispositivos según sea necesario, incluidos los instalados en la bahía de 5,25"...
Página 16
Case Storage CS380 Installation Chart Remove expansion slot covers to install required expansion cards. Unused slots should have covers installed Entfernen Sie Steckplatzabdeckungen, installieren Sie die gewünschten Erweiterungskarten. Bei nicht verwendeten Steckplätzen sollten die Abdeckungen angebracht bleiben Retirez les équerres pour installer vos cartes d'extension. Les emplacements inutilisés doivent garder leur équerre Quite las cubiertas de los zócalos de expansión para instalar las tarjetas de expansión necesarias.
Página 17
Case Storage CS380 Installation Chart Reinstall both left and right side panel to complete installation Installieren Sie zum Abschluss der Installation die linke und rechte Seitenwand wieder Réinstallez les deux panneaux latéraux pour terminer le montage Reinstale los paneles laterales izquierdo y derecho para completar la instalación Reinstallare entrambi i pannelli laterali per completare l’installazione...
Case Storage CS380 Connector Definition (1) Front Panel Connectors Power switch and reset switch installation guide Please refer to the motherboard manuals for the motherboard’s “Front Panel Connector” or “System Panel Connector” pin definitio Power switch and reset switch have no polarity, so they can be connected in any orientation.
Página 19
Case Storage CS380 Connector Definition LED indicators installation guide Please refer to the motherboard manuals for the motherboard’s “Front Panel Connector ” or “System Panel Connector” pin definition.; the white/black wires are negative while other colors are positive wires. The Power LED wires are separate pins for compatibility with different motherboard pin definition so please make sure they are connected in the right polarity by referring to your motherboard manual.
Página 20
A continuación tiene la definición de pines de los conectores frontales de E/S, también debe consultar el manual de su placa base para comprobar la referencia de los pines para E/S frontales. Los conectores de E/S de SilverStone son de bloque para simplificar la instalación.
Case Storage CS380 Guide to hard drive backplane 1.There are one 4pin peripheral connector and three 15pin SATA connectors, SAS8 SATA8 please do not connect all of them from one single cable from the power supply. Please connect them with at least two cables directly from the power supply.
Case Storage CS380 Component Size Limitations The CS380 can accommodate all standard size components and even some that are out of spec, please refer to the following guidelines for component selection and future upgrade considerations: (1) CPU cooler height limitation 146mm Height limitation for CPU cooler is 146mm with 5mm clearance over the motherboard’s top edge...
Página 23
Component Size Limitations (2) Power supply limitation A : Length limitation The length limitation is 250mm. If redundancy is required, we recommended SilverStone’s GM500-ATXG, an ATX redundant power supply that can fit inside the CS380. B : Power supply cable length recommendation Below is the recommended cable length for retail Micro-ATX motherboards.
Página 24
Component Size Limitations A : Limitazione della lunghezza l limite di lunghezza è di 250 mm. Se si richiede ridondanza, si consiglia GM500-ATXG di SilverStone, un alimentatore ridondante ATX integrabile con CS380. B : Raccomandazioni sulla lunghezza del cavo d’alimentazione Di seguito sono elencate le lunghezze raccomandate dei cavi d’alimentazione per le schede madre Micro-ATX vendute al dettaglio.
Página 25
PCIE 8/6 ピン (最初の拡張スロットまで) 200mm А : 길이 제한 제한 길이는 250mm입니다. 여분의 전원이 필요한 경우, CS380에 꼭 맞는 ATX 예비 전원공급장치인 SilverStone의 GM500-ATXG를 사용할 것을 권장합니다. B : 권장 전원 공급장치 케이블 길이 다음은 소매 Micro-ATX 메인보드용 권장 케이블 길이입니다. 케이블이 충분히 길지 않을 경 웅연장 케이블을 구매하십시오...
Página 26
Case Storage CS380 Component Size Limitations (3) Graphics card / expansion card limitation 9.5" (241mm) 5.9" (149mm) There is a length limit of 9.5" (241mm) and width limit of 5.9" (149mm) Es gilt eine Längenbeschränkung von 241,3 mm und eine Breitenbeschränkung von 149,86 mm Il y a une limite de longueur de 9,5"...
Optimal Thermal Performance Layout (1) CPU Cooler If you are installing a tower-style CPU cooler, we recommend that the CPU fan blows rearward to work with CS380’s overall airflow d th t th CPU f Falls Sie einen tower-artigen CPU-Kühler installieren, empfehlen wir, den CPU-Lüfter die Luft nach hinten blasen zu lassen, damit er mit der gesamten Luftbewegung im CS380 zusammenarbeitet Si vous installez un dissipateur de processeur de type "tour", nous vous recommandons que le ventilateur du dissipateur souffle vers...
Página 28
Lorsque vous choisirez une carte graphique, nous recommandons les modèles qui ont des ventilateurs qui soufflent en ext haut pour fonctionner dans le même sens que le flux d'air généré par le CS380 lui-même raction par l'équerre arrière, ceci assurera un flux d'air régulier et efficace dans le CS380 pour des performances de refroidissement maximales Cuando escoja una tarjeta gráfica, le recomendamos modelos que tengan la salido de aire del ventilador hacia el zócalo trasero, esto le asegurará...
Página 29
Case Storage CS380 Optimal Thermal Performance Layout (3) Tips For Cable Management Please refer to the following diagram. The 24pin and graphics card power cables are recommended to not be routed through the back side. CPU 8pin cable can be routed through the top hole. We recommend using two separate 4pin power cables for connecting to backplane.
El diseño de presión de aire positiva de la CS380 es una configuración efectiva que reducirá la acumulación de polvo dentro de la carcasa. Pequeñas partículas de polvo ó pelusa se irán acumularán con el transcurso del tiempo en los filtros de entrada en lugar de en los componentes del interior de la carcasa.
Página 31
Case Storage CS380 Upgrade And Maintenance (1) Fan filter removal guide After removing the side panel, loosen plastic pop rivets to remove filter Lösen Sie nach Entfernen der Seitenblende die Kunststoff-Blindnieten zum Entfernen des Filters Après avoir retiré le panneau latéral, desserrez les rivets en plastique pour enlever le filtre Tras retirar el panel lateral, afloje los remaches de plástico para retirar el filtro...
Página 32
Case Storage CS380 Upgrade And Maintenance PSU filter under the bottom panel can be removed by pulling it away from the chassis Den Netzteilfilter unter der oberen Abdeckung ziehen Sie einfach vom Gehäuse ab Le filtre PSU sous le panneau inférieur peut être retiré en le tirant hors du châssis El filtro de la fuente de alimentación bajo el panel inferior se puede retirar tirando de él hacia fuera del chasis...
Case Storage CS380 Q&A Q : There are lots of capacitors on the backplane, what are they used for? A : They provide additional power stability for hot-swapping hard drives F : Ich habe einen Alles-in-Einem-Flüssigkühler an CPU und Grafikkarte; wie installiere ich sie? A : Wir empfehlen, den Kühler der CPU vorne und den Kühler der Grafikkarte hinten zu installieren...
2. Under warranty, SilverStone Technology’s maximum liability is limited to the current market value for the product (depreciated value, excluding shipping, handling, and other fees). SilverStone Technology is not responsible for other damages or loss associated with the use of product.