6.3. Drainage
Fix the drainage bend pipe as shown in the figure
6.4. Electrical connection
WARNING: Risk of electrical shock.
To access the connection strip, remove the switch cover and attach the hose cable to the rear panel. In large
capacity models (group D) the electrical connections are located in the rear cabinet, the circuit breaker must be
set to "0" in order to open the door
Connect the terminal strip and check that the connections correspond to the operating voltage.
Place an autonomous power switch (I) at the current input, with a minimum of 3 mm between contacts. Fit a
300Ma differential protection.
INSTRUCTIONS FOR CONNECTING THE EARTH
This appliance must be connected to an earthed metal, permanent wiring system, or an earth conductor should
be installed with the circuit conductors and connected to the earth discharge terminal or the appliance cable.
WARNING! Specific models exist for 400V 3N~ and 230V 3~, the voltage cannot be changed by simply
changing the connections. To change an appliance to 400V 3N~ or 230V 3~, please refer to Technical
Service.
Connect the terminal strip and check that the connections correspond to the operating voltage.
Fit a 300mA differential protection.
The machine must be connected to earth.
400V 3 III+N+T
(Group D)
ye
bl
g
br
230V 3 III+T
5
A= Drainage pipe bend
B=Clamp
The drain flow rate for all models is up to 47 GPM (178 LPM). Be sure that
the system is designed to handle that flow rate. If multiple washers are
installed in line, be sure the system is designed to handle the combined flow
from all the washers.
400V 3 III+N+T
230V I+N+T