Trouble Shooting; Fault Correction - Deltafox DG-EHT 6051 Traducción Del Manual De Instrucciones Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 104
Noise and vibration values have been de-
termined according to the standards and
regulations mentioned in the declaration
of conformity.
The stated vibration emission value was
measured in accordance with a standard
testing procedure and may be used to
compare one power tool to another.
The stated vibration emission value may
also be used for a preliminary exposure
assessment.

Trouble Shooting

Problem
Device does not
start
Device runs with
interruptions
Blades (
8)
become hot
Possible cause
Mains voltage not on
On/Off switch (
defective
Worn carbon brushes
Defective motor
Power cable is damaged
Internal loose electrical
connection
On/Off switch (
defective
Blades (
8) are blunt
Blades (
8) are notched
Too much friction due to lack
of lubrication
Warning:
The vibration emission value may
differ during actual use of the
power tool from the stated value
depending on the manner in which
the power tool is used.
Safety precautions aimed at pro-
tecting the user should be based
on estimated exposure under
actual usage conditions (all parts
of the operating cycle are to be
considered, including, for example,
times during which the power tool is
turned off and times when the tool
is turned on but is running idle).

Fault correction

Check plug socket, cable, line and
plug, where appropriate, have
repaired through electrical specialist
3)
Repair by Service Centre
Check the cable and have it changed
by the Service Centre if necessary
Repair by Service Centre
3)
Have the blades (
replaced (Service Centre)
Have the blades (
replaced (Service Centre)
Oil the blades (
GB
8) sharpened or
8) checked or
8)
25

Publicidad

Tabla de contenido
loading

Tabla de contenido