DC Current
Range
Resolution
200 µA
0.1 µA
2000 µA 1 µA
20 mA
10 µA
200 mA
100 µA
10 A
10 mA
Overload Protection:
F1: Fuse, 250 mA/300 V, fast action
Min. Interrupt Rating 1500 A
F2: Fuse, 10 A/300 V, fast action
(Note: 10A/300V FAST fuse can only be replaced at
specified service station.)
Max. Allowable Input Current: 10 A
(for measurements >2A: measurement duration
<10seconds at intervals >15 minutes apart)
* If the current being measured is > 10A, the
display may show the value of the current; but the
measurement is dangerous.
Diode and Continuity
Range
Description
The approx. forward voltage drop of the diode is shown on
the display.
The built in buzzer will sound if the resistance is less
than about 30 Ω. The buzzer may or may not sound if the
resistance is between 30 Ω and 150 Ω. The buzzer will not
sound if the resistance is more than 150 Ω.
Temperature
Range
0°C - 400°C
400°C - 1000°C
* If the temperature being measured is out of the range of 0°C - 1000°C, the display may show a reading;
Overrange
Accuracy
Indication
±(1.0% + 5)
"1" shown
on the
±(1.2% + 5)
display
±(2.0% + 5) —*
Resolution
1°C
Resistance
Range
Resolution
200 Ω
0.1 Ω
2000 Ω
1 Ω
20 kΩ
10 Ω
200 kΩ
100 Ω
2000 kΩ
1 kΩ
Max. Open Circuit Voltage: Approx. 2.8V
Accuracy
±(1.0% + 5)
±(1.5% + 15)
Overrange
Accuracy
Indication
±(1.2% + 5)
"1" shown
±(1.0% + 5)
on the
display
±(1.2% + 5)
Test Condition
Open Circuit Voltage:
approx. 2.8 V
Test Current: approx. 1 mA
Open Circuit Voltage:
approx. 2.8 V
Overrange Indication
—*
5