9. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly quali ed persons in order to avoid a hazard.
10. Warning: Reduce the working time to avoid risks related with too much vibration.
Residual risks
Even when the power tool is used as prescribed it is not possible to eliminate all residual risk
factors. The following hazards may arise in connection with the power tool's construction and
design:
1. Damage to lungs if an e ective dust mask is not worn.
2. Damage to hearing if e ective hearing protection is not worn.
3. Damages to health resulting from vibration emission if the power tool is being used over
longer period of time or not adequately managed and properly maintained.
WARNING! This power tool produces an electromagnetic eld during operation. This eld may
under some circumstances interfere with active or passive medical implants. To reduce the risk
of serious or fatal injury, we recommend persons with medical implants to consult their physi-
cian and the medical implant manufacturer before operating this machine.
Safety instructions
Application
- Drilling holes in concrete
- Crushing concrete, chipping, digging, and squaring (by applying optional accessories)
Werkzeugaufnahme // Toolholder
Leistung // Power
Stoßfestigkeit // Impact Rating
Geschwindigkeit // No - Load Speed
Schlagenergie // Impact Energy
Nettogewicht // NW
Maximale Bohrkapazität // Max drilling capacity
Meißelpositionierung // Chisel positioning
Lärm LPA // Noise LPA
Built to Exceed
Rotary hammer: 88.38 dB(A) / Chiselling: 94.88 dB(A)
3 YEARS
L I M I T E D WA R R A N T Y
SDS - Max
1.200 W
1.350 - 2.950 bpm
235 - 514 rpm
10 Joules
Drill bit: Φ42mm - Core bit: Φ110mm
6.5 Kg
12 Step
5