2
INSTALL REMOTE SWITCH
WARNING
BURN HAZARD
The remote switch must be located so that it can be
operated without reaching over the cooktop. Failure
to do so may result in ignition of clothing which
could cause serious injury or death.
Determine the location for the remote switch.
• Disconnect the remote switch from the harness.
• The remote switch should be located so that
the vertical distance from the floor to the remote
switch is less than 48" and more than 15".
• The remote switch harness is 68" long and
should be installed so that it is not pinched and is
away from moving parts.
Remote Switch
Foam Piece With
Adhesive Mounting
Surface
Strain Relief
(Adhesive wire clamp
with tie)
• Use the remote switch to determine the exact
center of the hole, confirm there is clearance
behind the hole for the connector and wire to
pass into, and drill a ½" diameter hole.
• If the remote switch is not installed on the
countertop, ensure that it is installed in a location
that meets local codes and is easily accessible.
49-80777
Installation Instructions
1/2"-Dia. Hole
Remote
Harness
1/2"-Dia.
Hole
Remote
Switch
Foam Piece With Adhesive
Mounting Surface
Connect Remote Switch to Remote Harness
• Thread the remote harness through the 1/2"-dia.
hole and attach the harness connector to the
remote connector.
• Remove the paper backing on the remote switch
foam piece and mount the remote switch on the
countertop such that the switch connectors stay
located in the 1/2"-dia. hole.
• Stick adhesive wire clamp near the 1/2"-dia. hole
and attach the loose wire with a wire tie.
Mating Connectors
Strain Relief
(Adhesive wire
clamp with tie)
Control
Box
Connect Wire Lead to Control Box
• Connect the mating wire ends.
• Place the adhesive wire clamps (provided) near
the mating connector.
• Keep approximately 3"-long wire and attach
the wire to the clamp with a wire tie. This will act
as a strain relief.
Remote Harness
17