Configuration Options - Dell PowerConnect W-6000M Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33

Configuration Options

Configuration Requirements
The following requirements must be adhered to when running W-6000M3 Controller Modules within the Dell
PowerConnect W-6000:
The first W-6000M3 Controller Module must be installed in either Slot 0 or Slot 1 of the W-6000 chassis. W-
6000M3 modules in Slot 2 or Slot 3 will not boot if an W-6000M3 is not present in Slot 0 or Slot 1. Refer to
Figure 6
Slot 0 or Slot 1 must be populated before Slot 2 or Slot 3 since backplane communication occurs between the
following:
Slot 0 communicates with Slot 2 and/or Slot 3
Slot 1 communicates with Slot 2 and/or Slot 3
The W-6000M3 module is designed for installation within the W-6000 chassis utilizing 400 W power supplies
only. Refer to
Minimum software requirements must be met prior to installing the W-6000M3. Refer to
Software Requirements" on page 1
Figure 6
Configuration options are also dependent on power requirements for each module. Refer to
Management" on page 10
6
for Slot ID and locations within the Dell W-6000 chassis.
"Power Management" on page 10
W-6000 Slot Configuration
SLOT 2
SLOT 0
for complete details.
for complete details.
for complete details.
Dell PowerConnect W-6000M3 Controller Module | Installation Guide
"Minimum
SLOT 3
SLOT 1
"Power

Publicidad

Tabla de contenido
loading

Tabla de contenido