11. Possible causes of failure

Problem
The compressor does not start
The compressor starts but there is
no pressure
The compressor starts, but the
tools do not .
16
25.06.2010
8:32 Uhr
Seite 16
Cause
1. No supply voltage
2. Insufficient supply voltage
3. Outside temperature is too low
4. Motor is overheated
1. Leak in the non-return valve
2. The seals are damaged.
1. Loose hose connections
2. Leak in a quick-lock coupling
Solution
1. Check the supply voltage, the
power plug and the
socket-outlet.
2. Make sure that the extension
cable is not too long. Use an
extension cable with large
enough wires.
3. Never operate with an outside
temperature of below +5°C.
4. Allow the motor to cool down. If
necessary, remedy the cause of
the overheating.
1. Replace the non-return valve
2. Check the seals and have any
damaged seals replaced by a
service center
1. Check the compressed air hose
and tools and replace if
necessary.
2. Check the quick-lock coupling
and replace if necessary.