PROBLEM
The vacuum does not work.
The
aspiration
is
satisfactory.
Red light on- minimum
level in the boiler.
Red
light
on-
minimum
level in the boiler with the
presence of water in the
tank or boiler.
The floor has lines and the
appliance does not vacuum
well.
Glasses and flat surfaces
have lines on them.
CAUSE
Vacuum plug not inserted
correctly.
Switch on ergonomic handle
in "0" position.
Hose plug not connected
properly.
not
Clogged
accessories
plugs.
Squeegee suction nozzle
worn or damaged.
Lack of water in the boiler.
-
Floor
rubber
damaged.
Dirty rubber.
Ruined rubber.
Brush attachment mounted.
ENGLISH - 10
Professional Cleaning Machines Since 1968
SOLUTION
Check and insert the plug
into the socket head on the
base.
Press the switch.
Check that the plug and the
hose are properly connected
with the pin into its slot.
or
Check and clean the hose
and the suction nozzle.
Check
and
rubber.
Pour water into the boiler.
Contact
service center.
nozzle
Replace the rubber.
Clean the rubber with a
sponge.
Replace rubber.
Replace the brush attach-
ment with the rubber frame.
www.ghibliwirbel.com
replace
the
an
authorized