1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation avant
l'installation.
2.
This luminaire must be installed in accordance with the NEC
or your local electrical code. If you are not familiar with these
codes and requirements, consult a qualified electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n'êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualifié.
3.
This fixture is for indoor use and should not be used in areas
of limited ventilation or high ambient temperature.
Ce luminaire est conçu pour être utilisé à l'intérieur des
bâtiments. Ne pas installer dans les endroits à ventilation
réduite ou ayant une température ambiante élevée.
4.
Suitable for dry and damp location.
Convient aux emplacements secs et humides.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
FIXTURE INSTALLATION
1.
Pass the (2) supplied wire hangers through the last links of (2)
supplied suspension chains.
2.
Install the wire hangers into the back of the fixture,. Ends of wire
hangers are first inserted into the longer oval holes in the fixture
and are then returned out of the fixture through the smaller oval
holes.
3.
Once fully engaged into the fixture holes, close the ends of the
wire hangers using pliers.
4.
Hang opposite ends of chains at the desired suspension distance
following:
www.e-conolight.com
Document:
LPN00359X0001A0_A
Created By:
TMT
from an appropriate support member of the building structure.
Note: Support locations on building structure should be located so
both chains hang vertically from support points.
Note: Fixture must be fully supported from chains, independent of
the power supply cord.
INSTALLATION OF LENS ACCESSORY- FIG. 1
1.
Rotate (4) latches on lens fully clockwise.
2.
Position lens on fixture.
3.
Rotate (4) latches fully counter-clockwise to engage latches with
openings in fixture housing.
FIGURE 1
ELECTRICAL CONNECTIONS
1.
Open both wiring access covers on top of the fixture by loosening
the thumb screws.
2.
Remove 1/2" knockout on top of fixture at end of fixture where
driver is mounted. If drivers are located on both wiring access
covers, the 1/2" knockout can be removed at either end of fixture.
3.
Insert cord through removed 1/2" knockout and snap strain relief
into knockout.
4.
Splice cord leads to leads on drivers as follows:
Fixture is equipped with universal volt driver 120-277V
(ie. 120V, 208V, 240V or 277V)
PHASE TO NEUTRAL WIRING 120/277V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply common to fixture neutral (white) lead.
3. Connect supply Vin to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
PHASE TO PHASE WIRING 208/240V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply L1 (Hot) to fixture neutral (white) lead.
3. Connect supply L2 (Hot) to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
5.
Close both wiring access covers and retighten thumb screws.
6.
Connect opposite end of cord to building's power supply.
7.
Restore power to fixture and verify proper operation.
|
888.243.9445
|
FAX: 262.504.5409
Date
2016-08-09
ECO#
006448
(4) Latches