INSTALLATION INSTRUCTIONS
E-AL and E-APA Series
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
should always be followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou
votre code électrique local. Si vous n'êtes pas familier
avec ces codes et ces exigences, veuillez contacter un
électricien qualifié.
3. Proper grounding is required to ensure personal safety.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
Notes:
1. Strain relief is required for electrical connections on 2" (51 mm
adjustable fitter mounts at heights of 25' (7.6 m) and above. Tie
a knot in the supply wires above the hole in the lower fitter wiring
compartment to reduce the strain on the connections. Make sure
knot will not slip through hole.
2. Strain relief is required for electrical connections on direct mounts
at heights of 25' (7.6 m) and above. Knot the supply wires from
the pole with the fixture cord inside the pole.
3. All wire connectors within the fixture must be rated for 90°C
minimum.
4. Fixture is only UL listed for downlight orientation. Can NOT be
used as an uplight.
5. Use this fixture installation sheet for installing, do NOT refer to
mounting accessory sheet for installing.
FIGURE 1
Hex Nut
Sealing Washer
Pole Cap
Extruded Arm
Cord
Backing
Plate
Threaded
Rod
www.e-conolight.com
|
Document:
LPN00365X0001A0_A
Created By:
TMT
NOTE: Fixture is only UL listed for downlight orientation.
NOTE: Strain relief is required for electrical connections at heights of
25' (7.6 m) and above. Knot the supply wires from the pole with the
fixture cord inside the pole.
1. Use Template 1 for dimensions on pole drilling if pole is not pre-
drilled. NOTE: Template is NOT to scale.
2. Screw threaded rods through holes in pole into backing plate inside
pole until non-threaded section of rod contacts pole wall.
3. Insert cord thru cord grip so that the leads with the ground lug
extend from the threaded side of the cord grip by 4" or as needed to
reach ground lug in fixture. Tighten cord grip firmly to cord.
4. Open fixture by removing ribbed driver compartment cover.
5. Insert cord into fixture and fasten cord grip to housing as shown in
Figure 1.
6. Connect cord ground wire to fixture ground. Connect cord white
wire to driver common wire. Connect cord black wire to driver
voltage wire.
7. Feed cord through extrusion into pole and slide extrusion over
threaded rods so that the rods rest in extrusion bosses
8. Align mounting holes of fixture with exposed end of threaded rod
and push fixture flush with extrusion.
9. Install 5/16" sealing washers and nuts onto threaded rods inside
fixture as shown (Figure 1), making sure the silicone sides (of the
washers) are placed against the inside wall of housing.
10. Torque 5/16" hex nuts to 132 in. lbs. (15 N-m).
11. Replace ribbed driver compartment cover that was removed in Step
4 above.
12. Make wire connections inside pole. See Fixture Wiring section.
13. Install pole cap.
TEMPLATE 1
Ø0.344"
(9 mm)
hole
2 Required
0.870"
(22 mm)
Ø0.500"
(13 mm)
hole
Pole
888.243.9445
|
FAX: 262.504.5409
Date:
2017-02-20
007091
DIRECT MOUNTING
NOT TO SCALE
2.000"
(51 mm)
2.000"
(51 mm)