Installation; Setting The Water Temperature; Facility Maintenance - Cleaning Function - geberit 115.728.21.1 Instrucciones De Instalación

Grifos electrónicos expuestos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Geberit Exposed Electronic Faucet
Installation & Maintenance Instructions
1. Turn off water supply to existing faucet and
remove faucet.
2. Mount the spout and rubber washer to top of
base. Another rubber washer, steel washer and
spout nut should be mounted underneath the
base. Securely tighten the spout nut.
Tighten spout nut securely to prevent spout
from rotating. If necessary, support spout from
above to prevent twisting. Do not overtighten
spout nut.
Do not use a wrench on spout or inlet tubes.
3. AC Only: Plug the power supply into the appro-
priate 110/115V wall outlet. Connect the power
supply female plug into the faucet male plug.
NOTE: Power supply is equipped with an 11.8"
(30cm) cord. For multiple faucet installation, an
additional extension cord is provided. Refer to the
wiring diagram packaged with the faucet.
4. Connect the hot and cold water lines to the sup-
ply pipes. Use Teflon tape on the threads to
ensure a leak-free joint. Tighten connections
securely.
5. Turn water supply on.
6. Remove protective covering from sensor.
7. Place hand in front of sensor for 15 seconds to
activate for the first time.
8. Faucet is now ready for use.
1. Remove the setscrew from
the rear of the spout.
2. Remove the spout.
It is not necessary to shut off
water supply to clean the
sink.
© 0504
Tag # T311
964.143.00.0

INSTALLATION

SETTING THE WATER TEMPERATURE

FACILITY MAINTENANCE - CLEANING FUNCTION

Rubber Washer
Rubber Washer &
Steel Washer
Battery Powered Faucet
3. Turn the adjustment screw
counterclockwise to lower the
water temperature or clock-
wise to raise the water tem-
perature.
4. Reinstall the spout and
setscrew.
1. Cover the sensor for 5
seconds.
2. Water flow will be halted
for 90 seconds.
3
Rubber Washer
Rubber Washer &
Steel Washer
AC Powered Faucet

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

115.729.21.1115.726.21.1115.727.21.1115.736.21.1115.737.21.1

Tabla de contenido