Don't open or repair the device by yourself.
Please report to an authorized Service Center if any unexpected operation or events occur.
Please use the soft cloth to clean the whole unit. Don't use any abrasive or volatile cleaners.
The device must be installed and put in service in compliance with the EMC information contained in this manual.
The portable and mobile radio communication devices may affect the functioning of the device
Do not use near (e.g. 1 m) a DEVICE for short wave or microwave therapy;
Do not connect the patient simultaneously to a high frequency electrosurgery device;
For all technical information please contact the Authorized Service Center JOYCARE
CAUTION: Do not forget: while self-measurement represents control, it does not constitute a proper diagnosis or treatment. Any unusual values should
always be discussed with your doctor. Under no circumstances should you change the dosage of any medication prescribed by your doctor. This
blood pressure monitor is not suitable for people with diagnosed cardiac arrhythmia. Should the user should suffer from heart problems, kidney
problems, diabetes and circulatory problems, it shall be necessary to seek the doctor's advice before using the device. This device is not a toy. Keep out
of reach of children. Do not leave it unattended and make sure that children do not play with it. This device shall not be used should you have any arm
wounds. This device should only be used for measuring blood pressure in adults. The device contains sensitive electronic components (Microcomputer).
Therefore, avoid strong electrical or electromagnetic fields in the immediate vicinity of the device (e.g. cell phones, microwave ovens). These can cause
a temporary loss of measurement accuracy. To avoid possible damage to the device, always use and store it within the temperature and humidity ranges
contained in the technical specifications.
POWER SPECIFICATIONS:
4 AA batteries included
DC 6 V power adaptor (not included)
Network adaptor connector
INSERTING AND REMOVING THE BATTERIES
Remove the cover on the battery compartment at the rear of the device and insert 4 new AA batteries, respecting the polarity indicated, then replace the
cover. Replace the batteries when the battery symbol
product is not used for an extended period of time, it is advisable to remove the batteries, since a leak from the batteries can cause damage to the device.
SETTING THE DATE AND TIME:
Before using your blood pressure monitor, you must set the date and time so that readings can be memorized with their date and time. Once the batteries
have been inserted, press and hold the "SET" key for approximately 3 seconds; the year will begin to flash on the display; now press the "MEM" key to
set the year, followed by "SET" to confirm; the month will start to flash, press the "MEM" key to set the month, then the "SET" key to confirm. Repeat
the same sequence to set the day, time and minutes. Once all the settings have been set, the display shows
automatically after a few seconds.
RECOMMENDATIONS FOR TAKING READINGS
5 minutes before taking a blood pressure reading, sit down, relax and remain calm. Wait at least 3 minutes between one measurement and the next.
Keep your body and arm cuff still and do not speak during the reading. Avoid touching the device. Always take readings on the same arm. Uncover your
arm so that it is exposed in the area in which the reading is being taken, and do not tighten the arm cuff excessively, allowing a space equivalent to the
width of a finger. Take your blood pressure reading while seated in an upright position, resting your lower arm onto a table or other surface. If necessary,
place something under your arm to adjust the height (e.g. a book). Relax your arm with the palm of your hand facing upwards. The arm cuff must be
positioned at the same level as your heart.
Because blood pressure varies throughout the day, it is advisable to measure your blood pressure always at the same time of day, so as to be able to
make a reliable comparison.
TAKING BLOOD PRESSURE READINGS
Connect the arm cuff's air tube to the main unit. Fit your arm in through the
arm cuff and pull the cuff so that it is positioned around 1 or 2 cm above the
fold of your elbow; the air tube must be positioned in line with your little finger.
Press the START/STOP button. All of the digits on the display will appear
simultaneously, then "O" will appear on the display, together with the arrow
appears on the display, and when the display starts to wane or doesn't power on. If the
14
, and the device will power itself off