Descargar Imprimir esta página

Sacopa Ø300 Manual De Instrucciones página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
IMPORTANT: The instruction manual you are holding includes essential information on the safety measures to be
implemented for installation and start-up. Therefore, the installer as well as the user must read the instructions before
beginning installation and start-up.
Keep this manual for future reference.
To achieve optimum performance of the Circular Ø300, follow the instructions provided below:
1. CHECK THE CONTENTS OF THE PACK:
The following accessories are included inside the box:
• Kibele Projector
2. GENERAL FEATURES:
This projector has been designed to be used in contact with water. It is class III electrical device with very low safety
voltage.
The projector complies with IPX8 degree of protection at a nominal immersion depth of 2 meters.
This projector complies with international safety standards for lights, especially the EN 60598-2-18 standard: LIGHTS
PART 2: SPECIFIC REQUIREMENTS SECTION 18 LIGHTS FOR SWIMMING POOLS AND SIMILAR APPLICATIONS.
The manufacturer is not liable in any case for assembly, installation or start-up of any electric components which have
been inserted or handled at locations other than its own premises.
3. INSTALLATION (Recommended):
Projector on the pipe
1. Screw the luminaire on the sleeve or pipe 1 ½ "up
to half the internal thread.
2. Screw one racord, reduction or appropriate to the
application site in the top half nozzle.
Attention:
• In water installations, ensure the body of the projector is located in an accessible place for easy handling, or
make sure it is easily removable.
• Before any handling ensure that there is NO voltage supplied to the projector.
4. SAFETY WARNINGS:
• People in charge of assembly should be suitably qualified for this type of work.
• Avoid making contact with the electric voltage.
• Comply with the current standards regarding accident prevention.
• In this regard, the IEC 364-7-702 standards must be observed: WIRING IN BUILDINGS. SPECIAL WIRING. SWIM-
MING POOLS.
• All maintenance operations should be performed with the projector disconnected from the Mains.
• Do not handle with wet feet.
5. ASSEMBLY AND FUNCTIONING WARNINGS:
• The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric
components which have been inserted or handled at locations other than its own premises.
• It is responsibility of the installer to ensure that no water gets inside the projector by means of the cables.
• This projector is resistant to pool treatments described below, always that the concentration values do not
exceed the following levels:
Chlorine
Bromine
Salt electrolysis (Na Cl)
Attention: Please note that the Ph of pool water always must be between 7.2 and 7.6.
• Bag with wall plugs and screws
TYPE OF TREATMENT
• Installation and maintenance manual
Tube or hose 1 ½" rush
CONCENTRATION IN WATER
2 mg/l
5 mg/l
6 g/l
2
Nozzle
Nozzle fitting
adaptation

Publicidad

loading