Installing a submersible well pump, continued.
Process D: Steps 1 through 4, At The House
STEP
1
Thread 10" x 1" nipple into pressure tank.
Thread tank cross #RTC290-1 into nipple so that
the two 1/4" holes in tank cross face upward.
Thread street tee into front of tank cross. Thread
pressure relief valve #RRV-75 into top of street
tee and thread 3/4" boiler drain into front of
street tee.
STEP
3
Thread one end of 1/4" x 3" brass nipple into
bottom of pressure switch #RPS. Thread other end
into left 1/4" hole of tank cross. Thread pressure
gauge #RG-2 into right 1/4" hole of tank cross.
Cut and cement as many sections and couplings
of PVC pipe needed to connect the 1" male
PVC adapter on the gate valve to 1" male PVC
adapter on the pitless slot assembly. Complete
installation should look like the drawing on the
following page.
1/4" X 3"
NIPPLE
CONSUMER HOT-LINE:
1-800-942-3343
Monday–Friday 7 AM to 5 PM EST
www.waterace.com
23833A09
T
ANK CROSS
#RTC 290-1
3/4" PRESSURE
RELIEF VALVE
#RRV-75
T
ANK CROSS
#RTC 290-1
3/4" BOILER
DAIN
PRESSURE
SWITCH #RPS
PRESSURE
GAUGE
#RG-2
(USA only)
STEP
2
Thread 1" male PVC adapter into the inlet side
of tank cross.
3/4" PRESSURE
RELIEF VALVE
#RRV-75
3/4" BOILER
DAIN
A typical submersible well
pump installation
9
1" MALE PVC
ADAPTER
1" MALE PVC
ADAPTER
Bag #23834A004