Troubleshooting - Generac GP Serie El Manual Del Propietario

Ocultar thumbs Ver también para GP Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting

PROBLEM
Engine is running, but
AC output is not
available.
Engine runs well at
no-load, but bogs when
load is applied.
Engine will not crank.
Engine will not start; or
starts and runs rough.
Engine shuts down
during operation.
Engine lacks power.
Engine surges or
stumbles.
18
CAUSE
1. Circuit breaker OPEN.
2. Poor connection or defective
cord set.
3. Connected device is bad.
4. Fault in generator.
5. GFCI receptacle is OPEN (if
equipped).
1. Short circuit in a connected
load.
2. Generator is overloaded.
3. Engine speed is too slow.
4. Shorted generator circuit.
1. 10 Amp fuse has melted open.
2. Battery weak or dead.
1. Fuel shut-off is OFF.
2. Dirty air filter.
3. Out of fuel.
4. Stale fuel.
5. Spark plug wire not connected
to spark plug.
6. Bad spark plug.
7. Water in fuel.
8. Overchoking.
9. Low oil level.
10. Excessive rich fuel mixture.
11. Intake valve stuck open or
closed.
12. Engine lost compression.
1. Out of fuel.
2. Low oil level.
3. Fault in engine.
1. Load is too high.
2. Dirty air filter.
3. Engine needs to be serviced.
1. Choke is opened too soon.
2. Carburetor is running too rich
or too lean.
CORRECTION
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is
in good condition.
4. Contact Authorized Service
Dealer.
5. Correct ground fault and press
reset button on GFCI recepta-
cle (if equipped).
1. Disconnect shorted electrical
load.
Know Generator Limits
2. See
3. Contact Authorized Service
Dealer.
4. Contact Authorized Service
Dealer.
1. Replace fuse.
2. Charge or replace battery.
1. Turn fuel shut-off ON.
2. Clean or replace air filter.
3. Fill fuel tank.
4. Drain fuel tank and fill with
fresh fuel.
5. Connect wire to spark plug.
6. Replace spark plug.
7. Drain fuel tank; fill with fresh
fuel.
8. Set choke to no choke posi-
tion.
9. Fill crankcase to correct level.
10. Contact Authorized Service
Dealer.
11. Contact Authorized Service
Dealer.
12. Contact Authorized Service
Dealer.
1. Fill fuel tank.
2. Fill crankcase to correct level.
3. Contact Authorized Service
Dealer.
1. Reduce load (see
erator Limits
2. Clean or replace air filter.
3. Contact Authorized Service
Dealer.
1. Set choke to halfway position
until engine runs smoothly.
2. Contact Authorized Service
Dealer.
Owner's Manual for Portable Generator
.