H-7860, H-7861
THINAIR
HAND DRYER
®
TOOLS INCLUDED
Tamperproof Wrench
WARNING! For proper electrical connections,
check the local building codes. The dryer must
be installed by a qualified, licensed electrician.
Check that the electrical supply corresponds to that
shown on the rating sticker of the unit. If the dryer is
connected to any electrical supply other than what is
stated on the rating sticker of unit, permanent damage
or improper, unsafe operation may result.
Make sure electricity is turned off at the main panel
before installing, maintaining or cleaning this hand
dryer. Dryer must be installed in accordance with
current local wiring and building regulations.
1.
Disconnect the power source previously brought to
the hand dryer location.
2. Lift cover up to remove from base plate. Use the
tamperproof wrench to remove the tamperproof bolt
on bottom of cover lifting upwards to remove cover
from baseplate.
3. If electrical wiring entry is to be made from the rear,
remove the appropriate pre-formed knockout on
the base plate.
a. For H-7860 only: If entry is to be made from the
side, knock out the pre-formed area on the
right side of cover for supply connection using
knockout gasket. A rigid conduit must be used.
4. Select the appropriate mounting height for dryer
and fastener. (See Figure 1) There should be no
obstruction between the hand dryer and the floor. If
mounting over a counter top, distance from counter
to dryer must be 15" minimum.
PAGE 1 OF 12
1-800-295-5510
uline.com
Knockout Gasket
(For H-7860 Only)
PRE-INSTALLATION WIRING
INSTALLATION
Pour le français, consulter les pages 9-12.
Do not wire this hand dryer into the lighting circuit. It
must be protected by an independent circuit.
The dryer is intended to be permanently connected to a
power supply and must be properly grounded.
SAFETY
Troubleshooting and inside maintenance must be
performed by qualified service personnel.
Do not use any power wash equipment for cleaning on
or near this unit.
Do not use the dryer for drying hair.
Do not obstruct air inlets or outlets.
Figure 1
MOUNTING HEIGHTS
(FLOOR TO BOTTOM OF UNIT)
Men's
45" (114 cm)
Ladies'
43" (109 cm)
Teenagers'
41" (104 cm)
Small Children
35" (89 cm)
Handicapped
37" (94 cm)
CAUTION! Do not use the base plate as a guide
when drilling. Make sure no pipe work (gas,
water, air) or any electrical cables or wires are
located directly behind the area to be drilled.
Para Español, vea páginas 5-8.
RECOMMENDED FASTENER
Masonry Wall
1/2" expansion
sleeve with 1/4"
lag bolt
Hollow Wall
1/4" wing type
toggle bolt
Wooden Wall
1/4" lag screw
with washer
0121 IH-7860