CODES
Flashing red LED light displays codes in the sensor behind air outlet.
Normal operation will be indicated by the red LED being on when not drying and off when hands are
under the sensor.
DRYER MAINTENANCE CODES
CODE
1 short / 1 long flash
1 short / 2 long flash
2 short / 1 long flash
MOTOR PROBLEM CODES
1 long / 3 short flash
1 long / 4 short flash
HEATER PROBLEM CODES
2 long / 3 short flash
ADJUSTING THE HEAT OUTPUT, MOTOR SPEED AND SENSOR RANGE
The dryer is shipped with maximum heat and maximum
motor speed. To adjust, turn the corresponding knob
counterclockwise to reduce.
NOTE: Knobs are located behind the dryer cover:
H = Heat
M = Motor
R = Range
PAGE 4 OF 12
TROUBLESHOOTING CONTINUED
OPERATING ISSUE
Clogged pre-filter
Severely clogged
pre-filter
In lockout mode
Motor current
too high
Motor curent
too low
Shorted or incorrect
heater
1-800-295-5510
RECOMMENDATIONS
Remove and clean pre-filter.
Remove and clean pre-filter.
Remove obstruction or
adjust sensor range.
Measure voltage across
terminal block. If voltage ok,
motor is pulling too much
current. Replace motor.
Measure voltage across
terminal block. If voltage ok,
motor is pulling too little
current. Replace motor.
Replace heating element.
• Heat – Air temperature (turn off to reduce energy
costs). When heat is off, the dryer is the same as the
XleratorEco version dryer.
• Motor – Air flow speed (lower to reduce energy costs).
• Range – The distance the sensor under the dryer,
used to recognize hands, will work.
NOTE: Eco
and are set with heat at minimum.
uline.com
RESULT
Dryer will continue
to run.
Dryer will stop.
Dryer will stop until
obstruction cleared or
sensor range is adjusted.
Dryer will stop.
Dryer will stop.
Dryer will stop.
models have no heating element
®