ERROR MEssAGE

In the case of operating faults or simply if an obstacle has been detected, press "OK" to view the cause "Fxx". The meaning of the error messages is given
in the following table:
MEssAGE
MEANING
Appears whenever an attempt is made to access the user interface while the gate is in motion.
0 (flashing)
Wait until the automation stops
F01
Problem detected in the circuit that activates the motor
F02
Obstacle detected which has impeded the normal opening movement
F03
Obstacle detected which has impeded the normal closing movement
F04
Obstacle detected by the photocells
F05
A condition has occurred which has caused the gate to stop moving
F06
An obstacle has been detected by the STPA input
F07
Serious EEPROM error
F08
Problem on encoder, check wiring
F09
TIME OUT error. The maximum time for completing the normal movement (when opening or closing) has elapsed, repeat the travel
learning procedure.
F10
F2 fuse blown
Press [OK] to make the error message disappear.

BACK-UP BATTERY OPERATION

The equipment can operate even in the event of mains power failure by means of the back-up battery.
Certain functions are disabled or reduced to maximise the number of arm movements.
the "AC" LED goes out
the display indicates: for the first 10 seconds, the message "BATT" alternated with the voltage taken at the battery terminals. After 10 seconds the display
switches off. To show the voltage again press the [OK] button
the arm moves at a constant speed, which in the event of mains power failure is slower than the normal speed
if the mains power is restored while the arm is moving, the arm speeds up slightly due to the increase in voltage, then pauses for a moment.
The movement then resumes at a slower speed and always in the open condition. This enables the equipment to realign itself.
The next time the gates are closed they will move at normal speed.
When running on battery power, the following functions remain active:
automatic reclosure
flashing light: switches on briefly BEFORE the movement starts (opening and closing) and then remains off
if an obstacle is detected, the movement stops. There is no reverse but the movement is slow, so a danger condition does not occur
However the following are deactivated:
AUX output
power to accessories (photocells etc) when the gate is stationary
2CAN output

Troubleshooting table

Possible problem
Automation does not work
Automation closes instead of opening Motor connection wires inverted
Automation does not close
Automation starts movement but then
inverts direction of movement
24
Cause
Mains power failure
Power fuses blown
Commands ineffectivei
Battery faulty
Photocells or safety device activated
Photocells or safety device activated
Electronic clutch is set to an excessively high sen-
sitivity level.
Encoder faulty.
In particular:
Corrective action
Check switch
Replace blown fuses with others of the same value
Check radio controls and selectors
Check battery state with flashing light
Check operation and alignment of photocells and safety device
Invert the terminal block of the electronic panel or the polarity of
the motor power cables
Check operation and alignment of photocells and safety device
Reduce sensitivity level of clutch.